Z10-30      

 

2.  Long press (5 secs) menu button to enter settings manually. Numbers will 

flash. Into corresponding settings page,  use plus/minus keys to adjust 
parameters to desired  value. After completion  cycling setting pages, 
system will automatically store changes into memory and exit setup menu. 

3.  In any interface from 2 to 5, long press (UP) to enter settings (store into 

memory). 
 

 

Function declaration 
 
1.  The floating voltage: float start voltage 
2.  Discharge recovery voltage: refers to the battery discharge, protection the 

battery voltage to restore voltage open the output 

3.  The discharge cut-off voltage: refers to the battery discharge voltage when 

the load off, to protect the battery, to prevent the battery over discharge 
damage 

4.  Load operation mode 

(24H) Load output 24 hours (except for battery under voltage) 

(1-23 H) Load on after sunset and closed after setting hours 

(0H) Dusk to down 

 

Note 
 
1.  The light control function is controlled by the solar panel, the use of light 

control function must access the solar panel. Otherwise, the light control 
will not have effect. 

2.  Load symbol  

 , only states that the load output has been turned on, and 

there is no connection to the load. 

3.  12V load outputs 120 W (max); 14V serves a maximum output of 240W. 

The load cannot  exceed the output power. If there is an inverter, the 
inverter can be directly connected to the battery, because the inverter itself 
comes with under voltage protection. 

4.  As long as it is not set to [1-23H] or [0H] (on optical display model) if battery 

is not under pressure condition (battery icon does no blink), load output 
can be turn on/off with a single short press on menu key. 

 