How-To: Using the IQ-501 with the Fiery server
12
8. Select
Create new calibration setting.
9. Optionally you may check
G7 gray balance
calibration target.
If you choose the G7 gray balance calibration
target the system will prompt you through
additional steps to print and have the IQ-501
scan G7 P2P targets. This is an iterative
process that allows you to build a neutral print
density curve on top of basic calibration.
These additional steps are not documented here,
however the FCPS software will prompt you
after the basic calibration to process the G7 P2P
targets. The G7 P2P targets can be iterated until
you are satisfied with the results. Once accepted
the profiling process continues as documented.
Refer to the contextual help icon for assistance
with the G7 workflow, or visit:
http://fiery.efi.com/help/G7CalibrationWorkflow