100 % Waterproof
Double-row LED bar
USER MANUAL EFFI-SMART-IP69K
Version 1.5.2022
Last update:
February 23, 2022
Mini Parc du Verger
–
Bâtiment E
1 Rue de Terre Neuve
91940 LES ULIS, FRANCE
Tel: +33 9 72 38 17 80
Fax: +33 9 72 11 21 69
Email: [email protected]
UK Importer: Gardasoft Vision Ltd.
Trinity Court, Buckingway Business Park
Swavesey, Cambrige CB24 4UQ UK
Page 3 / 4
The EFFI-Smart-IP69K is supplied with a 24V constant voltage. The AIC contact needs to be connected. Power consumption =
15W
for the 6LED version and
30W
for the 12LED version (for 2m cable).
Please make sure that the flying leads output of the cable is in a
sealed area.
Weather, bio oil, detergent and hot water resistant
Core insulation made of modified PP / Outer sheath made of special TPE / Sheath colour: black
Conductor n°
EFFI-SMART-IP69K
1
+24V
2
NPN TRIGGER (trigger on falling edge) for Auto-strobe
Light ON if V
NPN
<1.5 DC
Max consumption = 0.1mA
–
max 24V
–
Analog Voltage
3
GND
4
PNP TRIGGER (trigger for rising edge) for Auto-strobe
Light ON if V
PNP
> 3V DC
Max consumption = 2mA
–
max 24V
–
Analog Voltage
5
AIC : Analog Intensity Control for Dimming Control
Consumption = 1mA @10V & 2mA @24V
–
max 24V
–
Analog Voltage
Mode
Designation
Contact arrangement
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
AUTOSTROBE
PNP : Strobe control triggered on
rising
edge
N.B: For the strobe mode please respect a duty
cycle lower than 0.25
+24V
Not
connected
(≠0V)
GND
> 3V DC
Max 24V
DC
Not
connected
(≠0V)
NPN : Strobe control triggered on
falling
edge
N.B: For the strobe mode please respect a duty
cycle lower than 0.25
+24V
< 1.5V DC
GND
Not
connected
(≠0V)
Not
connected
(≠0V)
DIMMING CONTROL
Analog Intensity Control
LED OFF: 0-3V
LED ON: 3V (40%)
–
10V (100%)
LED ON: 10-24V (100%)
+24V
Not
connected
(≠0V)
GND
Not
connected
(≠0V)
AIC: 0-
24V
See
scheme
TEST MODE
LED are supplied with I
max
(700%) until
default temperature is activated. Do not
use with external trigger, just for
continuous.
Signal consumption : 4mA
Do not touch the product (WARM)
+24V
> 3V DC
Max 24V
DC
(or not
connecte
d)
GND
> 3V DC
Max 24V
DC
> 3V DC
Max 24V
DC
RISE
FALL
Rise time : 10 µs
Fall time : 10 µs
Response rise time : 30 µs
Response fall time : 30 µs (NPN : 20 µs)
Electronical consideration