background image

 

Structured LED lighting

 

USER’S GUIDE EFFI-LASE-V2 
Version 2.0.2017
 
Last update:
 August 17, 2017

 

 

 

 
 

 

Mini Parc du Verger – Bâtiment E 

1 Rue de Terre Neuve 

91940 LES ULIS, FRANCE

 

Tel: +33 9 72 38 17 80 

Fax: +33 9 72 11 21 69 

Email: [email protected]

 

 

Page 2 / 4

 

      
 

Mask  

Cover 

EFFM-SPANNER-WRENCH  

C-mount 

Optical Head 

 

 

 

EFFI-LASE-PSV 
EFFI-LASE-FAN 

-XXX 

-YYY 

 -ZZZ 

 

 

 

 

 

 

 

 

LED version 

Wavelength (nm) 

Type of mask 

 

LX1 

MX1 
MX2 
MX3 

 

385 / 395 / 405 

465 
525 
625 
850 

000 (White) 

L01 (1 line 50µm) 

L02 (1 line 100µm) 

L03 (1 line 10µm) 

L04/05 (3 lines 50 µm) 

L06 (5 lines 50µm) 

L07 (100 lines 45µm) 

L08 (22 line 50µm) 

L09 (1 line 5µm) 

L41 (1 line 75µm 40 lines 45 µm) 

G01 (Round 50µm) 
G02 (Round 50µm) 

G03 (Grid 40*40 lines 50µm) 
G04 
(Grid 50*50 lines 50µm) 

G05 (Squares 50*50µm²) 
C02 
(Cloud of dots 50%) 
C03 
(Cloud of dots 17%) 

A01 (Cross 50µm) 

A02 (Concentric circles) 

A03 (Square 50µm) 

 

 

Regardless of maintenance, the product must be switch off. For more information, please refer to the datasheet.  

CHANGE THE MASK 
 

 

 

Reference  

Maintenance 

To handle the optical components, wearing gloves is strongly recommended. 
To clean the optical components: Use compressed air duster if there is dust.  
To remove marks on the lens or the window, just a drop or two wiped of alcohol-based lens cleaning fluid in a gentle circular motion 
with a cleaning tissue. Always apply the fluid to a tissue rather than the lens itself.

 

Place the new mask (here, L03)

 

4

 

Unscrew the C-mount & ring

 

2

 

Remove the mask & cover

 

3

 

Place delicately the cover & ring

 

5

 

Screw the C-mount & optical head

 

6

 

Unscrew the optical head (2x screws)

 

1

 

Summary of Contents for LASE V2 PSV

Page 1: ...ssification PSV Protected from limited dust ingress protected from water spray from any direction IP40 Classification FAN Protected from tools greater than 1mm not protected from water Use the device...

Page 2: ...s 50 m G04 Grid 50 50 lines 50 m G05 Squares 50 50 m C02 Cloud of dots 50 C03 Cloud of dots 17 A01 Cross 50 m A02 Concentric circles A03 Square 50 m Regardless of maintenance the product must be switc...

Page 3: ...x 24V 3mA 24V 1 If the AIC is not connected the light will light on at 100 as if VAIC 24V If you don t need to adjust light level do not connect use this PIN MODES CONTROL MODE DESCRIPTION SCHEME Auto...

Page 4: ...rsion 2 0 2017 Last update August 17 2017 Mini Parc du Verger B timent E 1 Rue de Terre Neuve 91940 LES ULIS FRANCE Tel 33 9 72 38 17 80 Fax 33 9 72 11 21 69 Email contact effilux fr Page 4 4 PSV VERS...

Page 5: ...ns n importe quel autre liquide Code IP40 FAN Prot g contre les corps solides sup rieurs 1mm non prot g contre l intrusion d eau Utiliser le produit dans un environnement dont la temp rature de travai...

Page 6: ...Grille 50 50 lignes 50 m G05 Carr s 50 50 m C02 Nuage de points 50 C03 Nuage de points 17 A01 Croix 50 m A02 Cercles concentriques A03 Carr 50 m Le produit doit tre HORS TENSION Pour plus d informatio...

Page 7: ...ue Max 24V 3mA 24V Si le AIC n est pas connect la lumi re va s allumer 100 comme si VAIC 24V Si vous n avez pas besoin d ajuster l intensit lumineuse ne pas utiliser connecter ce PIN CONTR LE DES MODE...

Page 8: ...ao t 2017 Mini Parc du Verger B timent E 1 Rue de Terre Neuve 91940 LES ULIS FRANCE Tel 33 9 72 38 17 80 Fax 33 9 72 11 21 69 Email contact effilux fr Page 4 4 Dimensions Fixations VERSION PSV en mm...

Reviews: