Adjustable beam power ring
USER’S GUIDE EFFI
-RING
Version 2.2.2020
Last update:
June 17, 2020
Mini Parc du Verger
–
Bâtiment E
1 Rue de Terre Neuve
91940 LES ULIS, FRANCE
Tel: +33 9 72 38 17 80
Fax: +33 9 72 11 21 69
Email: [email protected]
Page 2 / 4
EFFI-RING
-XXX
-YY
-ZZ
-
…
Wavelength (nm)
Windows
Lens position
Option
405
465
525
625
850
000 (White)
RGB
(625 +525+465)
WUI
(000+405+850)
TR
(Transparent)
SD
(Semi-diffusive)
OP
(Opaline)
P0
(no lens)
P1
(45°)
P2
(25°)
P3
(10°)
POL
(polarizer)
-POL-IP
(polarizer glued for IP version)
STR
(driving control)
Please note that with the polarizer accessory, the EFFI-Ring is IP50. For IP65 polarized version, choose -POL-IP option.
Regardless of maintenance, the product must be switch off.
CHANGE OPTICAL CONFIGURATION
Reference
Maintenance
Take out the mechanical parts
2
Replace the lenses in the right position
4
Unscrew the M2 screws
1
To handle the optical components, wearing gloves is strongly recommended.
To clean the optical components: Use compressed air duster if there is dust.
To remove marks on the lens or the window, just a drop or two wiped of alcohol-based lens cleaning fluid in a gentle circular motion with a
cleaning tissue. Always apply the fluid to a tissue rather than the lens itself.
Hex Key
Size: 2
Take out the block of lenses
3
P0 P1 P2 P3