CONTACT ARRANGEMENT 

The EFFI-LASE-CPT is supplied with a direct current through the connector 

M8 Male 8 contacts

. The power consumption depends on the 

intensity which flows through the LED and on the LED version.  

M8 connector 

 direct control (expert mode)

 

Pin 

number 

Cable 

color 

Contact arrangement 

With MX1 

or LX1  

With MX2 

With MX3 

White 

 

M8 Male 8 contacts 

-V

LED

 

-V

LED 

n°1 (Z2) 

-V

LED 

n°1 (Z2) 

Brown 

+V

LED

 

+V

LED

 n°1 (Z2) 

+V

LED

 n°1 (Z2) 

Green 

N.C 

-V

LED

 n°2 (Z1) 

-V

LED

 n°2 (Z1) 

Yellow 

N.C 

+V

LED

 n°2 (Z1) 

+V

LED

 n°2 (Z1) 

Grey 

N.C 

N.C 

-V

LED

 n°3 (Z3) 

Pink 

N.C 

N.C 

+V

LED

 n°3 (Z3) 

Blue 

-TH 

Thermistor 

-TH 

Thermistor 

-TH 

Thermistor 

Red 

+TH 

Thermistor 

+TH 

Thermistor 

+TH 

Thermistor 

 
 

LED arrangement 

LX1 

MX1 

MX2 

MX3 

 
 

 

 

 
 

 

 

 

 

 

 

 

 

 

 

 
 

STROBE CONTROL

 

You can see below 5 possible configurations depending on the current that you provide to the EFFI-LASE-CPT. 

 

 

 
 

 
 
 
 

 

 

Configuration 

Current 

Max pulse duration (µs) / τ

pulse 

1.2A 

50000 

0.5 

1.5A 

10000 

0.1 

2A 

1000 

0.01 

2.5A 

100 

0.001 

3.5A 

40 

0.0004 

Electronical consideration 

Electrical diagram for each channel :   

Protective diode 

D

 TVS 400mW 24V : 

PTVS24VS1UR 

Thermistor NTC 10k

Ω

TH1

 : 

VISHAY NTCS0805E3103JMT 

Summary of Contents for effiLase V2

Page 1: ...the projection lens IP54 Classification Protected from limited dust ingress protected from water spray from any direction Use the device in an environment at 0 C to 40 C with no excessive moisture hig...

Page 2: ...04 Grid 50 50 lines 50 m G05 Squares 50 50 m C02 Cloud of dots 50 C03 Cloud of dots 17 A01 Cross 50 m A02 Concentric circles A03 Square 50 m Regardless of maintenance the product must be switch off Fo...

Page 3: ...MX3 1 White M8 Male 8 contacts VLED VLED n 1 Z2 VLED n 1 Z2 2 Brown VLED VLED n 1 Z2 VLED n 1 Z2 3 Green N C VLED n 2 Z1 VLED n 2 Z1 4 Yellow N C VLED n 2 Z1 VLED n 2 Z1 5 Grey N C N C VLED n 3 Z3 6...

Page 4: ...configurations The selection between configuration 1 and configuration 2 depends on the object to observe either the specular reflection needs to be captured configuration 1 or reflections different...

Page 5: ...ion Code IP54 Ne pas immerger le produit dans l eau ou dans n importe quel autre liquide Utiliser le produit dans un environnement dont la temp rature de travail est situ e entre 0 C et 50 C et peu hu...