CONTACT ARRANGEMENT
The EFFI-SHARP-CPT is supplied with a direct current through the connector
M8 Male 8 contacts
. The power consumption depends on the
intensity which flows through the LED and on the LED version.
M8 connector
–
direct control (expert mode)
Pin
number
Cable
color
Contact arrangement
With MX1
With MX2
1
White
M8 Male 8 contacts
-V
LED
-V
LED
n°1 (Z2)
2
Brown
+V
LED
+V
LED
n°1 (Z2)
3
Green
N.C
-V
LED
n°2 (Z1)
4
Yellow
N.C
+V
LED
n°2 (Z1)
5
Grey
N.C
N.C
6
Pink
N.C
N.C
7
Blue
-TH
Thermistor
-TH
Thermistor
8
Red
+TH
Thermistor
+TH
Thermistor
LED arrangement
MX1
MX2
STROBE CONTROL
You can see below 5 possible configurations depending on the current that you provide to the EFFI-SHARP-CPT.
Configuration
Current
Max pulse duration (µs) / τ
pulse
D
1
1.2A
50000
0.5
2
1.5A
10000
0.1
3
2A
1000
0.01
4
2.5A
100
0.001
5
3.5A
40
0.0004
Electronical consideration
Electrical diagram for each channel :
Protective diode
D
TVS 400mW 24V :
PTVS24VS1UR
Thermistor NTC 10k
Ω
TH1
:
VISHAY NTCS0805E3103JMT