background image

 

Adjustable beam power ring

 

USER MANUAL EFFI-RING-HSI 

Version 1.2.2022

 

Last update:

 February 23, 2022

 

 

 

 
 

 

Mini Parc du Verger 

 Bâtiment E 

1 Rue de Terre Neuve 

91940 LES ULIS, FRANCE

 

Tel: +33 9 72 38 17 80 

Fax: +33 9 72 11 21 69 

Email: [email protected]

 

UK Importer: Gardasoft Vision Ltd. 

Trinity Court, Buckingway Business Park 

Swavesey, Cambrige CB24 4UQ UK

 

Page 2 / 4

 

      

 

 

 

 

EFFI-RING 

-HSI 

-YY 

-ZZ 

-

 

 

 

 

 

 

 

 

 

 

 

Wavelength (nm) 

Windows 

Lens position 

Option 

 

Hyperspectral Visible-NIR 

TR 

(Transparent)

 

SD 

(Semi-diffusive)

 

OP 

(Opaline)

 

P0 

(no lens) 

P1 

(45°) 

P2 

(25°)

 

P3 

(10°)

 

POL 

(polarizer) 

-POL-IP

 (polarizer glued for IP version) 

STR 

(driving control)

 

 

Please note that with the polarizer accessory, the EFFI-Ring is IP50. For IP65 polarized version, choose -POL-IP option. 

 

 

During any maintenance operation, the product must be switched off. 

HOW TO CHANGE THE OPTICAL CONFIGURATION

  

 

          

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                    

 

 

 

 

 

 

Reference  

Maintenance 

To handle the optical components, wearing gloves is strongly recommended. 
To clean the optical components: Use compressed air duster if there is dust.  
To remove marks on the lens or the window, just a drop or two wiped of alcohol-based lens cleaning fluid in a gentle circular motion with a 
cleaning tissue. Always apply the fluid to a tissue rather than the lens itself. 

    P0              P1               P2               P3 

Numbers 1, 2 and 3 are inscribed 

on the edge of the lens plate 

and 

correspond to the lens position. 

Rotate 

the lens to align the number of the desired position with the 

outgrowth of the light. 
 
1) Unscrew the M2 screws and separate all parts. 
2) Align the lens plate to the desired position and place into the light. 
3) Place the lens holder, then the desired diffuser. 
4) Close the product. 

 

 

Summary of Contents for EFFI-RING-HSI

Page 1: ...id any contact with the LED or with the projection lens IP65 Classification Do not immerse the device in water or any other liquids Operating environment 0 to 40 C Humidity 20 to 85RH without condensation High humidity and high temperature could damage the device Do not use the device in an environment with oil fumes and steam Do never try to fix any damages to the product by yourself Make sure yo...

Page 2: ...P option During any maintenance operation the product must be switched off HOW TO CHANGE THE OPTICAL CONFIGURATION Reference Maintenance To handle the optical components wearing gloves is strongly recommended To clean the optical components Use compressed air duster if there is dust To remove marks on the lens or the window just a drop or two wiped of alcohol based lens cleaning fluid in a gentle ...

Page 3: ... effilux fr UK Importer Gardasoft Vision Ltd Trinity Court Buckingway Business Park Swavesey Cambrige CB24 4UQ UK Page 3 4 SPOT DIAMETER VS WORKING DISTANCE Transparent Semi Diffuse Opaline Ø Spot SPECTRUM Measurements done on EFFI RING HSI SD P2 at 10mm working distance after 30min of use 0 0 2 0 4 0 6 0 8 1 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 Relative Irradiance u a Waveleng...

Page 4: ...either to the 24V DC signal for Continuous mode or to a PNP Trigger signal for Strobe mode M12 connector Smart control Continous or Strobe Contact arrangement Number Color Contact Designation M12 Male connector 1 Brown 24V 2 White n a 3 Blue GND 4 Black PNP TRIGGER max 24V Light on if VPNP 5V DC 5 Grey n a M8 connector Direct control expert mode Contact arrangement Number Color Contact Designation...

Page 5: ...ni Parc du Verger Bâtiment E 1 Rue de Terre Neuve 91940 LES ULIS FRANCE Tel 33 9 72 38 17 80 Fax 33 9 72 11 21 69 Email sales effilux fr UK Importer Gardasoft Vision Ltd Trinity Court Buckingway Business Park Swavesey Cambrige CB24 4UQ UK Page 5 4 DIMENSIONS in mm FIXING in mm Mechanical consideration ...