USER MANUAL EN EFFI-FLEX-LG V1.1.2022

How to connect the EFFI-LINE3 ?

Power Supply

The consumption values are maximum values, the exact power consumption of the product is always indicated on the product label.

ELECTRICAL INSTALLATION - STD CONNECTOR CONFIGURATION

Power Supply Voltage

24V DC +10%/-0

Connector(s) 

(Depending on the power consump

-

tion - See page 6)

 

M12 Power (T-Coded) - 

(See wiring layout page 6) 

4 pins at the end of a 500 mm cable length

Flying leads 1 - 1 power input - 

(See wiring layout page 6)

 

XX m long, section 2.5 mm²

Flying leads 2 - 2 power inputs - 

(See wiring layout page 6)

 

XX m long, section 2.5 mm² x2

Average Power Consumption 

Standard version

 

(Cable not included in the calcu

-

lation)

IR 850 nm

Red 625 nm

Blue 465 nm

White 5500K

Max. 8W per 100 mm

Max. 10W per 100 mm

Max. 12W per 100 mm

Max. 12W per 100 mm

Analog Intensity Control (AIC)

The output optical power is adjustable from 10% to 100% by applying a signal from [1.5V-10VDC]

Total voltage range [1.5V-24VDC] / Don’t exceed 24V DC

 

Max. signal consumption: 4mA

Trigger Input signal

PNP trigger input: Light ON: from 5V to 24V / Don’t exceed 24V DC / Max. signal consumption: 4mA

(Option NPN on PIN4: Light ON: from 0V to 1.5V 

Don’t exceed 24V DC / Max. signal consumption: 4mA)

Note : 

For POWER version with (-WTR), the housing must be connected to the ground thanks to the ground connection kit that 

comes with the product.

Mode control

1 +24V

 

Brown cable

TRIGGER PNP 4 

Enable pin 

Light ON if V

PNP

> 5V DC) 

Black cable

GND 3

 

Blue cable

2

 

AIC 1.5-10V

 

Analog Intensity Control

Grey cable

The EFFI-LINE3 requires 24V DC input power. Depending on the size and the version, the light comes with different connectors and 

cables. 

(See the tables below)

M12 Power (T-coded) - 4 pins

male connector - 500 mm cable length

Flying leads FL1

Flying leads FL2*

Wire index

Designation

1

+24V

2

NC

3

GND

4

Trigger PNP (or NPN)

5

AIC

6

NC

7

NC

Wire index

Designation

1

+24V

2

GND

3

GND

4

Trigger PNP (or NPN)

5

AIC

6

+24V

7

NC

*WARNING with FL2: 

Wire 1,2,3 and 6 must be connected as indicated in the table aboveor the 

cable may be damaged. Both GND have to be connected together.

Illumination mode

Continuous

Strobe

Signal to 

apply on

 

PNP

A continuous signal must be 

applied with V

PNP

> 5V DC

A trigger signal must be applied

 

Light ON if V

PNP

> 5V DC

 

Light OFF if V

PNP

< 2.5V DC

Signal to 

apply on 

AIC

By default, if AIC is not connected, the light is ON at 100%

 

V

AIC 

[

1.5

-

10V]

 

to adjust the intensity from 10% to 100% 

(see the graph)