USER MANUAL EN EFFI-FLEX-LG V1.1.2022
How to connect the EFFI-LINE3 ?
Power Supply
The consumption values are maximum values, the exact power consumption of the product is always indicated on the product label.
ELECTRICAL INSTALLATION - STD CONNECTOR CONFIGURATION
Power Supply Voltage
24V DC +10%/-0
Connector(s)
(Depending on the power consump
-
tion - See page 6)
M12 Power (T-Coded) -
(See wiring layout page 6)
4 pins at the end of a 500 mm cable length
Flying leads 1 - 1 power input -
(See wiring layout page 6)
XX m long, section 2.5 mm²
Flying leads 2 - 2 power inputs -
(See wiring layout page 6)
XX m long, section 2.5 mm² x2
Average Power Consumption
Standard version
(Cable not included in the calcu
-
lation)
IR 850 nm
Red 625 nm
Blue 465 nm
White 5500K
Max. 8W per 100 mm
Max. 10W per 100 mm
Max. 12W per 100 mm
Max. 12W per 100 mm
Analog Intensity Control (AIC)
The output optical power is adjustable from 10% to 100% by applying a signal from [1.5V-10VDC]
Total voltage range [1.5V-24VDC] / Don’t exceed 24V DC
Max. signal consumption: 4mA
Trigger Input signal
PNP trigger input: Light ON: from 5V to 24V / Don’t exceed 24V DC / Max. signal consumption: 4mA
(Option NPN on PIN4: Light ON: from 0V to 1.5V
/
Don’t exceed 24V DC / Max. signal consumption: 4mA)
Note :
For POWER version with (-WTR), the housing must be connected to the ground thanks to the ground connection kit that
comes with the product.
Mode control
1 +24V
Brown cable
TRIGGER PNP 4
Enable pin
Light ON if V
PNP
> 5V DC)
Black cable
GND 3
Blue cable
2
AIC 1.5-10V
Analog Intensity Control
Grey cable
The EFFI-LINE3 requires 24V DC input power. Depending on the size and the version, the light comes with different connectors and
cables.
(See the tables below)
M12 Power (T-coded) - 4 pins
male connector - 500 mm cable length
Flying leads FL1
Flying leads FL2*
Wire index
Designation
1
+24V
2
NC
3
GND
4
Trigger PNP (or NPN)
5
AIC
6
NC
7
NC
Wire index
Designation
1
+24V
2
GND
3
GND
4
Trigger PNP (or NPN)
5
AIC
6
+24V
7
NC
*WARNING with FL2:
Wire 1,2,3 and 6 must be connected as indicated in the table aboveor the
cable may be damaged. Both GND have to be connected together.
Illumination mode
Continuous
Strobe
Signal to
apply on
PNP
A continuous signal must be
applied with V
PNP
> 5V DC
A trigger signal must be applied
▪
Light ON if V
PNP
> 5V DC
▪
Light OFF if V
PNP
< 2.5V DC
Signal to
apply on
AIC
By default, if AIC is not connected, the light is ON at 100%
V
AIC
[
1.5
-
10V]
to adjust the intensity from 10% to 100%
(see the graph)