background image

Part No. 007-5600-003, Rev C

6SHHG6WUHDP

Ù

'6/5RXWHU

,QVWDOODWLRQ*XLGH

6HULHV

Summary of Contents for SpeedStream 5600 Series

Page 1: ...Part No 007 5600 003 Rev C 6SHHG6WUHDP 6 5RXWHU QVWDOODWLRQ XLGH 6HULHV...

Page 2: ......

Page 3: ...re from any devices onto which you have installed it and must ensure that the party to whom you transfer the Hardware receives this License Agreement and Limited Warranty 4 Upgrades Covered This licen...

Page 4: ...oduct have been tampered with 2 the Product s case has been opened or 3 there has been any attempted or actual repair or modification of the Product by anyone other than an EFFICIENT authorized servic...

Page 5: ...E AMOUNT PAID FOR THE HARDWARE SOFTWARE 3 General This Software License and Limited Warranty will be covered by and construed in accordance with the laws of the State of Texas United States excluding...

Page 6: ...4 Efficient Networks...

Page 7: ...sing DHCP to Assign an IP Address 13 Manually Assigning an IP Address 14 Step 2 Setting the Password 14 Step 3 Configuring the Router 14 Configuring the Router through the Web Interface 14 Configuring...

Page 8: ...rface 21 Step 5 Testing the Configuration 23 Step 6 Optional FTP Access for Firmware Configuration Uploads 23 Appendix A Types of User Interfaces 25 Web Interface 25 Command Line Interface 26 Command...

Page 9: ...referred to in this manual primarily as a router it can be used as either a router or a bridge Instructions for changing from router mode to bridge mode are included on page 18 About this Installatio...

Page 10: ...ed 5600 router Power supply for either a 220v or a 110v electrical outlet One RJ45 or RJ11 unshielded twisted pair UTP cable for the DSL connection One RJ45 UTP crossover cable for connecting to an Et...

Page 11: ...ng the gray RJ45 cable which is a straight through cable Connect to an Ethernet hub or switch using the crossover cable labeled XOVER on one end NOTE Some Ethernet hubs and switches have an Uplink por...

Page 12: ...u set the connectors of each side by side you can see that the RJ45 connector is wider than the RJ11 Figure 3 RJ45 and RJ11 Comparison e5006 071000 Plug cable into DSL wall jack Router Power Gray RJ45...

Page 13: ...elf test The sys light turns green when the unit has finished passing diagnostic tests 2 The dsl light will flash green while the router is attempting to obtain the optimum transmission rate over the...

Page 14: ...tact customer support to report problem POST Failure contact customer support to report problem POST Failure contact customer support to report problem POST Failure contact customer support to report...

Page 15: ...Setup portion of the web based management interface for instructions on setting up NAPT to enable WAN side access Step 1 Assign an IP Address to your PC Using DHCP to Assign an IP Address Before you...

Page 16: ...ing the current password and a blank for the new password If the password is forgotten the router can be set to the factory default state from the serial port during the boot process Refer to Restorin...

Page 17: ...look in the Configuration Summary table and click on the title Encapsulation Protocol 4 Click the button for the type of virtual connection VC you want to create 5 If your service provider has specif...

Page 18: ...ser s Guide Method 1 Via Telnet 1 Start your Telnet client If you are using Windows on a PC select Start Run and enter telnet 10 0 0 1 If you are on a UNIX system type telnet 10 0 0 1 2 The Telnet cli...

Page 19: ...a Web browser and accessing a remote web site such as http www efficient com Alternatively you can open an MS DOS or shell window and issue a ping ip_address command to a known host on the wide area...

Page 20: ...command line interface Changing to Bridge Mode through the Web Interface 1 Start your web browser 2 Enter the router s IP address 10 0 0 1 3 On the first page click on the link Change to Bridge Mode...

Page 21: ...will be prompted to reboot the unit Enter the reboot command at the prompt and press Enter 5 You will then be prompted to confirm your request Type y for yes and press Enter Any existing Telnet sessi...

Page 22: ...0 0 0 Default gateway 10 0 0 1 Step 3 Setting the Password The bridge has no password protection as configured from the factory As soon as you log into the bridge you should set the password This can...

Page 23: ...and skip to step 9 6 Select the desired RFC 1483 multiplexing method LLC or VCMUX 7 Select Max as the rate 8 Click on the Create VC button to set new parameters or select Set Defaults to return to th...

Page 24: ...y configuration parameters as prompted The bridge can also be reset to the factory default configuration from the command line interface using the default all command Method 2 Via a the Serial Port 1...

Page 25: ...own host on the wide area network Step 6 Optional FTP Access for Firmware Configuration Uploads Using FTP you can Upload a new revision of the router firmware Save the router s current configuration t...

Page 26: ...24 Bridge Configuration Efficient Networks...

Page 27: ...ing the current configuration of the router The first page also has a menu with links to the following web pages Simple Setup Presents configuration forms where you can enter the minimum configuration...

Page 28: ...POST error messages will be displayed to the serial console Contact Efficient Networks Customer Support to report the problem Using the Command Line Interface The following commands and keystrokes can...

Page 29: ...rs If you type the command name and press Enter you will be prompted for each parameter When being prompted for a command argument or Scrolls through the keywords This control only works for arguments...

Page 30: ...28 Types of User Interfaces Efficient Networks...

Page 31: ...erating Mode Router Ethernet Interface IP Address 10 0 0 1 Network Mask 255 0 0 0 IP Gateway Default Route Address None DSL WAN Interface IP Address None Network Mask None Data Encapsulation Protocol...

Page 32: ...ing the following procedure To reset router to the factory default state 1 Access the router through the serial port 2 Enter the reboot command 3 During the boot process the screen will start displayi...

Page 33: ...rating 0 to 40 C Non Operating storage 10 C to 85 C Humidity Operating humidity 10 to 90 noncondensing Non operating storage humidity 5 to 95 non condensing Ringer Equivalency REN 0 8B Performance Mee...

Page 34: ...g 0 to 40 C Non Operating storage 10 C to 85 C Humidity 10 to 90 noncondensing Non operating storage humidity 5 to 95 non condensing Ringer Equivalency REN 0 8B Performance Meets or exceeds requiremen...

Reviews: