USV ME400/500/600/650/800
Instruction Manual
ME series
Page 29 of 32
14 Technical Data
14.1 Equipment specifications
Model:
ME400
ME500
ME600
ME650
Power:
400VA /
225W
500VA /
250W
600VA /
300W
650VA /
325W
Mains power
input:
Phases
1 phase con neutral conductor
Input range
170-280V AC
Rated frequency
50 / 60Hz
Synchronous range
45-65Hz
Boost (+13%)
yes
Buck (-13%)
yes
UPS output:
Rated voltage (support
mode)
230V AC
(modified sine +/-15%)
Max. output current
1.7A
2.1A
2.6A
2.8A
Bridging time
6 min.
6 min.
4 min.
4 min.
Efficiency:
AC -> AC
> 94%
DC input
Input voltage
12V DC (rated)
Interface:
LAN / RS232
9-pin D-SUB socket or USB
(galvanically isolated)
Environmental
data:
Perm. temp. range
0...+40°C
Recommended temp.
+15...+25°C
Storage temperature
0...+40°C
Rel. atmos. humidity
0...90% (non-condensing)
Standards:
EN 50091-1, EN 50091-2
General
Cooling
Convection cooling without fans
Noise level
<35dB
Weight
5.4kg
5.8kg
5.8kg
5.8kg
Inspections
TÜV / GS / CE
Dimensions
H x B x D [mm]
171 x 95 x 357mm