Efergy Elite Classic Manual Download Page 16

  Multiple tariff 

You will only need to use this setting if you have dual or multiple tariffs

Press and hold the 

MODE/SET

 button for 2 seconds. Press the 

MODE/SET

 button two more times to 

find the tariff mode. Use the 

BACKWARD

 

 and

 FORWARD

 

 to choose between tariff periods 

1

2

,

 3 

or

 4

Press the 

MODE/SET

 button to confirm and will move to set the start and end of the tariff period. Use 

the 

BACKWARD

 

 and

 FORWARD

 

 buttons to set the start time for tariff.  Press the 

MODE/SET 

button to 

set the end of the tariff using the 

BACKWARD

 

 and

 FORWARD

 

 buttons again. Press the 

MODE/SET

 

button to finish. Repeat this process to configure each tariff period.

15

Summary of Contents for Elite Classic

Page 1: ...Efergy Elite Classic FW No 4 0...

Page 2: ...s and transmitter 3 Link the transmitter and monitor MONITOR SETUP Setting time and date Voltage Currency Tariff period Tariff pricing Carbon emissions ration Maximum power alert Temperature Multiple...

Page 3: ...ount of energy that a household is consuming at the time the display is read The display can also give the user a reading showing usage in financial terms You can walk around the home with your monito...

Page 4: ...rs are simple to install and use A CT sensor is clipped onto the live feed cable of your breaker panel A lead from the sensor is connected to the Efergy Transmitter This Transmitter wirelessly sends r...

Page 5: ...lth and safety issues which you need to be aware of The current sensors clip onto the supply cables inside the main electrical panel which delivers power to your home Do not touch any metallic connect...

Page 6: ...in the sensor Even with the main breaker in the off position the connection lugs where the main wires terminate at the main breaker may still be live with potentially lethal voltage Stay clear of thes...

Page 7: ...your power meter fuse box There are a couple of options here you can install the clamp either onto your incoming mains cable this will check you overall power or onto a separate individual circuit lik...

Page 8: ...ou live in an apartment it may be in the kitchen a utility closet or hallway Remove the outside cover from your electrical panel and locate the main feed wires You should find up to four feed wires en...

Page 9: ...TH CAUTION For example if you have a single tariff meter you should find four cables exiting the meter see Diagram A The feed cable is the live cable exiting from the meter to the fuse box or main swi...

Page 10: ...ace it around the feed cable and push the clasp to shut Efergy recommends high quality alkaline or lithium batteries for the best product performance Battery life will depend on environment up to 12 m...

Page 11: ...back of the monitor and hold for two seconds The transmission signal symbol will flash for one minute or until the transmitter and monitor are linked While the transmission signal symbol in the displ...

Page 12: ...larm settings The following steps will move through each of these settings 11 Humidity Time and date Forward Backward Temperature Push HISTORY button at any time your settings will be saved and you wi...

Page 13: ...s Once the correct time and date have been set push the MODE SET button to save and move onto the date setup Set the month by using the BACKWARD and FORWARD buttons Press the MODE SET and move onto th...

Page 14: ...different world currencies available Kr R Press and hold the MODE SET button for 2 seconds Select the currency using the BACKWARD and FORWARD buttons Default currency will be Push MODE SET button to c...

Page 15: ...d if you go over your set maximum power consumption target Use the BACKWARD and FORWARD buttons to increase or decrease the value and press the MODE SET button to confirm Press MODE SET button to move...

Page 16: ...ARD and FORWARD to choose between tariff periods 1 2 3 or 4 Press the MODE SET button to confirm and will move to set the start and end of the tariff period Use the BACKWARD and FORWARD buttons to set...

Page 17: ...he display s battery cells This icon displays the amount of power left within the transmitter s battery cells GET FAMILIAR WITH THE DISPLAY ENERGY NOW The home screen of the display is the ENERGY NOW...

Page 18: ...to access daily weekly and monthly stored data Use the BACKWARD and FORWARD buttons to scroll between dates and compare consumption data Press the MODE SET button to change information from kWh to co...

Page 19: ...d your home energy consumption how much energy you re using and which appliances are costing you most Save money Use the real time average and historic consumption information to help you change habit...

Page 20: ...ansmission time Transmission range Working voltage range Measuring current Carbon ratio Designed in the UK Made in the PRC Certifications ELITE 4 0 433 5MHz 10s 130 230ft 40 70m 120 240V 60Hz 50mA 120...

Page 21: ...er advice on monitoring electricity at home please feel free to contact us or visit the website for up to date information downloads and frequently asked questions Website www efergy com Support site...

Page 22: ...www efergy com...