steady mode
Features &
Controls:
Front Panel
10
Digital Display
•
Teach
button
. In Teach mode, you can “teach” the deposit based
on physical size.
• Press the
button once, so that the digital display flashes.
• Press and hold the foot pedal to establish your deposit size.
Tapping the foot pedal repeatedly will have a cumulative effect
on the dot size and dispense time.
• Press
button again. The flashing stops. Your dispense
time is now automatically stored, with the decimal displayed
in the appropriate position.
• Press twice to clear the display. Any decimals will disappear and
the time range will reset to 000.
•
Steady
button
. In Steady mode, the foot pedal controls fluid flow.
•
Press once and the display changes to dashes
(---)
.
•
Press again and dashes are replaced with dispense time setting.
•
Steady mode is used for filling the dispense tip, dispensing
beads and stripes of material, and making by-eye deposits.
•
Decimal
button
. Press the Decimal button to move the
decimal. When no decimal shows, the dispense time range is .000 to
.999 seconds. Note: You cannot adjust the decimal from Teach mode
(when display is blinking).
•
Time Set
buttons
. Each button sequentially controls the display digit
in that panel. Each press advances the display from 0 to 9 and repeats.
air pressure regulator
vacuum regulator
air output
teach
pressure gauge
time set buttons
decimal button
digital display
0
5
0
5
0
0.
0
0
5.
.050 seconds
0.50 seconds
5 seconds