Step 3.

Install retainer and rotate clockwise

to secure. Connect HP7x to EFD

air-powered dispenser. Insert air

quick-connect into air outlet and 

turn clockwise to lock.

Changing Tips

Remove tip retaining cap and invert.

Align slot with wings on dispensing tip.

Turn tip retaining cap counterclockwise

to remove tip. Attach a new tip and

tighten tip retaining cap securely.

For parts list, see back cover.

+

+

quick-connect

tip retaining cap

Note: 

Refer to EFD dispenser operating instructions to control deposit size with time and pressure.

Do not reuse reservoirs!

Wipe plunger clean (if necessary) before installing a new reservoir.

window

Changing Reservoirs

When a reservoir is empty,

the window in the air cylinder

will turn red. Remove reservoir

retainer. Then, remove empty

reservoir and discard.