Original operating manual
Pneumatic circular saws
OM No.: 001 580 654
16 of 19
Version
26.06.2018
Silencer (here EFA SK 08 D)
7.3.2
Sharpening the saw blade
ATTENTION
Incorrectly sharpened saw blades
lead to production losses and
endanger the user.
For sharpening, please contact the
sharpening service of the nearest
authorized workshop or contact our
head office directly.
Sharpening can also be carried out on
commercially available automatic circular saw
blade sharpening machines.
More detailed information on sharpening the
saw blade relating to the different saw blade
geometries (tooth shapes) is available on
request from our service department.
ATTENTION
Do not use force as parts could be
damaged! Only use original EFA
spare parts!
7.3.3
Maintenance unit
For proper operation and to maintain the
adequate service life of the pneumatic circular
saw, the maintenance unit (filter pressure
reducer) must be checked at regular intervals.
Remove any condensation and, if
necessary, fill up with special oil (available
from S&W).
Check the operating pressure (max. 8 bar)
at regular intervals.