EENOUR Mate 2 User Manual Download Page 4

To prevent injury to the user or other people and property damage, the following 

instructions must be followed. 

WARNING: This symbol indicates the possibility of death or serious injury. 

 

Installation must be performed according to the installation instructions. Improper installation may 
cause water leakage, electrical shock, or fire. 

 

Use only the included accessories and parts, and specified tools for the installation. Using non-
standard parts may cause water leakage, electrical shock, fire, and injury or property damage. 

 

Make sure that the power outlet you are using is grounded and has the appropriate voltage. The 
power  cord  is  equipped  with  a  three-prong  grounding  plug  to  protect  against  shock.  Voltage 
information can be found on the side of the unit. 

 

DO NOT modify the length of the power cord or use an extension cord to power this product. Do 
not share a single outlet with other electrical appliances. Improper power supply can cause fire or 
electrical shock. 

 

Install the air conditioner on a flat, sturdy surface. Fail to do so could result in damage or excessive 
noise and vibration. 

 

The air conditioner must be kept free from obstruction to ensure proper functioning and to mitigate 
safety hazards. 

 

DO NOT install your air conditioner in a wet room such as a bathroom or laundry room. Exposure 
to water can cause electrical components to short circuit.   

 

DO NOT install your air conditioner in a location where may be exposed to combustible gas, as this 
could cause fire. 

 

DO NOT operate a unit that has been dropped or damaged. 

 

Only use the included accessories and specified parts for installation. Using nonstandard parts may 
cause water leakage, electrical shock, fire and injury or property damage. 

 

DO NOT allow children to play with the air conditioner. Children must always be supervised around 
the unit. 

 

In a thunderstorm, the unit should be turned off to avoid damage due to lighting. 

 

If the air conditioner is knocked over during use, turn off the unit and unplug it from the main power 
supply immediately. Visually inspect the unit to ensure there is no damage. If you suspect the unit 
has been damaged, contact a technician or customer service for assistance. 

 

Notes on fluorinated gases 

 

This air conditioning unit is a sealed unit containing a fluorinated gas. For information 

on  the  specific  gas  types  and  quantities,  see  the  relevant  label  on  the  device  or 

specification. This product does not support user adding refrigerant themselves.   

 

Maintenance or repair of this device must be performed by a certified technician. 

 

Product recycling must be performed in accordance with local regulation. 

 

 

 

Summary of Contents for Mate 2

Page 1: ...Portable Air Conditioner for Tent Camping Model Name Mate 2 Model No SQN750 User Manual V1 0 ...

Page 2: ...efully and keep it for future reference The specifications and design are subject to change without prior notice for product improvement or upgrade All illustrations in this manual are for illustration only Consult with your dealer or manufacturer for more detail ...

Page 3: ...ance to national regulation standards by qualified personnel only CAUTION This symbol indicates possibility of injury or damage to property This product is not intended for use by persons including children with reduced physical sensory or mental capabilities unless they have been given supervision or instruction concerning use of the product by a person responsible for their safety This product s...

Page 4: ...hazards DO NOT install your air conditioner in a wet room such as a bathroom or laundry room Exposure to water can cause electrical components to short circuit DO NOT install your air conditioner in a location where may be exposed to combustible gas as this could cause fire DO NOT operate a unit that has been dropped or damaged Only use the included accessories and specified parts for installation...

Page 5: ...5 than ambient temperature in 10 minutes The product was designed to achieve compact size and lightweight with classic handle for easy carrying Power consumption 200w 240w per hour 2kwh battery is able to last working about 10 hours 1 Control Panel 2 Outlet of cooled air 3 Inlet of air to evaporator 4 Inlet of air to condenser 5 Exhaust air outlet 6 Drain 7 Power input ...

Page 6: ...choose the 1 3 Fan speed SLEEP mode Long press the SLEEP mode button The COOLING mode is off the SNOW icon will disappear the compressor and exhaust fan will be turned off In SLEEP mode Long press the SLEEP mode button will switch to COOLING mode Temp Temp Adjust range 16 30 USE YOUR Mate 2 ...

Page 7: ...r conditioner power interface Solar panel 24V 10A Note The plug in T on the power port corresponds to the adapter plug An additional power cable is provided to allow for multiple applications of the product this device can be used with your outdoor batteries RV power supply etc Must meet DC 24V standard at least 10A current supply Accessory Connection Drain pipe connection instructions ...

Page 8: ... the hose is facing down to allow the water to flow smoothly Accessory Connection Exhaust hose connection instructions Process Twist the air duct pipes into Venting hose connection adapter Assemble connection adapter to exhaust stick the locating pins and hook at the bottom edge of adapter to the corresponding holes then push the release button to make sure adapter fixed well Adjust the length and...

Page 9: ...ss If the size is not enough big cut out some other foam and stick them together 4 Choose the right angle and place it on the window Close the window and insert the exhaust pipe into the round hole Use duct tape to stick and seal up the gap between pipe and the hole if necessary Cautions when placing exhaust hose To ensure proper functioning do not extend or bend the hose excessively Make sure the...

Page 10: ...ir reaching the position you want After installation hold the adapter with one hand when pulling the air duct to the desired position USE ENVIRONMENT Your installation location should meet the following requirements Make sure that you install your air conditioner on an even surface to minimize noise and vibration If using with a power adapter the device must be put near a grounded plug When the de...

Page 11: ...s Pay attention to tent insulation If the tent is poorly insulated cover the tent with an insulated mat Pay attention to the tightness of the tent For tents with vents close or cover the vents Pay attention to shade the tent it is recommended to use it in the shade If it is a large tent beyond the cooling range of Mate 2 please add one or more air conditioners or create a small cooling space with ...

Page 12: ...clean the device DO NOT wash the device under running water Doing so may causes electrical danger and damage Always clean the device using a damp lint free cloth and mild detergent Dry the device with a dry lint free cloth Malfunction Diagnosis Symptom Possible Cause Solution Control Board no Control board and control Contact the consumer service ...

Page 13: ... source if possible The unit is low on refrigerant Contact the consumer service The unit is noisy and vibrates too much The floor is not level Place the unit on a flat hard surface The unit makes a gurgling sound The sound is caused by the flow of refrigerant This is normal Unit stops frequently The exhaust hose is blocked or restricted Remove the exhaust hose to check if the unit runs again If ye...

Page 14: ...r 1pc Screw for Cold wind duct adapter M4 12 2pcs Duct pipe 2pcs AC DC power adapter Optional 1pc Drain pipe 1pc DIY cord with M16 4 conn ector 1pc Statement Please note that below situation or inappropriate operation will cause no warranty of this product ...

Page 15: ... the product is found damaged was not stopped operation and disconnected with power If the product was damaged mechanically or due to overvoltage If the product was being modified repaired or transformed without a written permission from our company ...