EEMB LIR18650 Specification Download Page 6

Document Name

Document No.

Ver

Date

Page

LIR18650

Specification

ZJQM-RD-SPC-A12112

0.0

2017-8-28

6/9

 

d.Impedance Meter
Impedance shall be measured by a AC impedance method (AC 1kHz LCR meter).

6.6 Rest period

Unless otherwise defined, 30 min, rest period after charge; 30 min, rest period after discharge.

7. Battery Pack’s Dimension

1. Drawing

Diameter

max

=19.5mm

Height

max

=70.5mm

2

Materials

Cell

LIR18650

Inside PCM

Note: Kind in prevail

8. Specification of PCM (inside)

The specification shall be applied to Lithium polymer battery protection circuit module manufactured by

EEMB CO., LTD.

8.1 Protection Circuit Diagram

Summary of Contents for LIR18650

Page 1: ... Battery Specification Model LIR18650 Capacity 2600mAh Prepared Checked Approved Customer Customer Approval Customer confirmation Signature Checked Approved Address Room ABCD 25 F Block A Fortune Plaza NO 7060 Shennan Road Shenzhen China Postal code 518040 Phone 0086 755 83022275 FAX 0086 755 83021966 http www eemb com ...

Page 2: ...Ah 2 Nominal Voltage 3 7V Mean Operation Voltage 3 Voltage at end of Discharge 3 00V Discharge Cut off Voltage 4 Charging Voltage 4 2V 5 Open Voltage 3 7 3 9V 6 Load Voltage 3 6V 10Ω 7 Energy 9 6Wh 8 Internal Impedance 150mΩ AC 1KHZ after 50 charge 9 Standard charge current 520mA 10 Standard discharge current 520mA 11 Maximum Charge Current 2600mA Ambient temperature 0 40 12 Maximum Continuous Dis...

Page 3: ...itive class having inner impedance more than 10kΩ V 5 2 3 Ammeter Standard class specified in the national standard or more sensitive class Total external resistance including ammeter and wire is less than 0 01Ω 5 2 4 Impedance Meter Impedance shall be measured by a sinusoidal alternating current method 1kHz LCR meter 6 Battery Performance Test 6 1 Initial Performance Test No Items Testing method ...

Page 4: ...f 45 75 then charge with 0 2C to 4 2V then shift to charge with constant voltage after full charge rest for 0 5h then discharge with 0 2C to 3 00V The discharge time is required 4h 6 2 Safety Test No Items Test method and determinant standard 6 2 1 High Temperature Characteristics Under the temperature of 23 2 after charging the battery with 0 2C then put the battery into the constant temperature ...

Page 5: ...n leakage rust smoking and explosion After testing take out the battery then rest for 2h under the temperature of 23 2 discharge with 0 2C to 3 00V The discharge time is required 72min 6 2 7 Drop Test Under the temperature of 23 2 after full charging the battery with 0 2C then drop it freely from 1 meter height onto the hard board which 18 20mm thick 6 times each of X Y Z with positive and negativ...

Page 6: ...od Unless otherwise defined 30 min rest period after charge 30 min rest period after discharge 7 Battery Pack s Dimension 1 Drawing Diameter max 19 5mm Height max 70 5mm 2 Materials Cell LIR18650 Inside PCM Note Kind in prevail 8 Specification of PCM inside The specification shall be applied to Lithium polymer battery protection circuit module manufactured by EEMB CO LTD 8 1 Protection Circuit Dia...

Page 7: ...it protection detection delay time 220 380uS 10 Shirt circuit release condition Cut off load 11 Current consumption in normal operation 7uA 12 Inner resistance 65mΩ 8 3 Part List Location Description part No Specification Size Qty Vendor ROHS Remar k U1 Protection IC G3J SOT 23 6 1 ROHS Q1 SMD MOSFET 8205 TSSOP 8 2 ROHS R1 SMD Resistance 470Ω 5 1 10W 0402 1 YAGEO ROHS R2 SMD Resistance 2KΩ 5 1 16W...

Page 8: ...ng is not completed within the specified time Stop using the Cell if abnormal heat odor discoloration deformation or abnormal condition is detected during use charge or storage Keep away from fire immediately when leakage or foul odor is detected If liquid leaks onto your skin or clothes wash well with fresh water immediately If liquid leaking from the Cell gets into your eyes do not rub your eyes...

Page 9: ...wing temperature ranges Charge temperature range 0 45 Discharge temperature range 20 60 Storage temperature range up to 30 days 20 45 Storage temperature range up to 90 days 10 35 Special Notice Keep the cells in 50 charged state during long period storage We recommend to charge the battery up to 50 of the total capacity every 6 months after receipt of the battery and maintain the voltage 3 6 3 9V...