If it displays with a message of “Battery Level = 255(0xFF)”, it implies that the 
Bell is at low battery status.  Please replace the batteries as soon as 
possible. 

 

 

2.  Z-Wave’s Groups (Association Command Class Version 2)

 

 
Door Bell can be set to send reports to associated Z-Wave devices.    It supports 
one association group with 5 nodes. 
 
2-1 ASSOCIATION_GET 
 

ASSOCIATION_GET Command 

[Command Class Association, Association Get]

: enquire Door Bell about 

relevant information of Grouping 1. 
ASSOCIATION_REPORT Command 

[Command Class Association, Association Report]

: report relevant 

information of Grouping 1. 

 

 

ASSOCIATION_GROUPING_GET Command 

[Command Class Association, Association Grouping Get]

: enquire how 

many Groupings can be supported by the Door Bell. 
ASSOCIATION_GROUPING_REPORT Command 

[Command Class Association, Association Grouping Report]

: report 

Door Bell can support 1 Grouping.

 

 

2-2 ASSOCIATION_SET 

 

ASSOCIATION_SET Command 

[Command Class Association, Association Set]

: decide which note 

is/nodes are to be placed in Grouping 1. 

 

 

2-4 ASSOCIATION_REMOVE (V2) 

 

ASSOCIATION_REMOVE (V2) Command 

[Command Class Association, Association Remove]

: decide which note 

is/nodes are to be excluded from Grouping 1 of Door Bell.

 

 

Note: 
 

1.  If the Door Bell is changing playing status (e.g. from NOT playing to playing), the   

Door Bell will report its status (SENSOR_BINARY_REPORT) to nodes of 
Grouping 1. 

 

2.  If battery level of Door Bell drops to an unacceptable level, the Door Bell will emit 

BATTERY_REPORT “Battery Level = 255 (0xFF)” to the nodes of Grouping 1. 

3. Command 

Class

 

     

The Door Bell supports Command Classes including… 

 

* COMMAND_CLASS_BASIC 
* COMMAND_CLASS_VERSION 
* COMMAND_CLASS_BATTERY 
* COMMAND_CLASS_SWTICH_BINARY 
* COMMAND_CLASS_SENSOR_BINARY 
* COMMAND_CLASS_ASSOCIATION_V2 
* COMMAND_CLASS_MANUFACTURER_SPECIFIC 

 
Troubleshooting 
 

Device Symptom  Possible 

Cause 

Recommendation 

Run out of battery power 
or does not fit batteries 

1.  Replace a new battery 
2.  Refit the battery with 

correct polarity 

Button or LED is 
damaged 

 
 
 
Push Button 

 
LED indicator is 
not working after 
Button is 
pressed 

The device is not 
working 

 
Call to the local service for 
repair 

Run out of battery power 
or does not fit batteries 

1.  Replace a new battery 
2.  Refit the battery with 

correct polarity   

Bell doesn’t 
sound after 
Music Selector is 
pressed 

The button is damaged 

Call to the local service for 
repair 

The user hasn’t logged 
in to the Administrator   

Log in to Administrator to 
execute the program     
 

 
 
 
 
 
Door Bell 

 
Door Bell.exe 
cannot be 
executed 
 

Being blocked by 
antivirus software or 
firewall 

Close the firewall or 
antivirus software 
 

 
Specifications 
 

                     

Model No. 

Item 

 

TAC06-JOEL Push Button 

Battery 

1.5V AAA size x 2 

Range 

Up to 30 m line of sight 

Frequency Range 

868.42 MHz 

Summary of Contents for TSE03-JOEL

Page 1: ...ill flash when Button is pressed When this occurs please replace the batteries as soon as possible Product Overview Push Button 1 LED Indicator Button 3 I R Key 2 Holes for Wall Mounting 4 A E Key Doo...

Page 2: ...ashes 3 times rapidly E Exclusion Push Button Press A E Key 3 times within 1 5 secs and within 1 sec press A E Key again for 5 secs until LED is off LED flashes on off alternately for 30 secs Door Bel...

Page 3: ...ush Button means inclusion Excluding a node ID allocated by Z Wave Controller means exclusion Please also note Push Button 1 Z Work network supports multiple controllers so you can use additional Push...

Page 4: ...sert the supplied plastic wall plugs and then screw the rear cover to the wall using the supplied screws FIGURE 5 4 Refit the Push Button to the rear cover Door Bell 1 Insert a flat bladed screwdriver...

Page 5: ...tion Pane a list of songs stored in the folder is displayed Clipboard A temporary storage area for selected songs They will be downloaded to the Bell once Download Key as shown in FIGURE 10 is pressed...

Page 6: ...ass Switch Binary Switch Binary Get enquire the current status of the Door Bell i e Door Bell is playing or not playing a song currently SWITCH BINARY REPORT Command Command Class Switch Binary Switch...

Page 7: ...from NOT playing to playing the Door Bell will report its status SENSOR_BINARY_REPORT to nodes of Grouping 1 2 If battery level of Door Bell drops to an unacceptable level the Door Bell will emit BAT...