EECI ADC-T Series Technical Reference Download Page 1

TABLE OF CONTENTS

            

Specifications.......................................... page 1

            

Connection Diagram and Warranty......... page 2

            

Technical Support................................... page 2

            

Terminal Block Connections.................... page 2

            

Set-Up and Testing................................. page 3 & 4
Device Manager...................................... page 4
Trouble-Shooting..................................... page 5

          

Input & Relay Expansion Ports............... page 5
The ADC-T User Interface.............

page 6

Auto Start-Up.......................................... page 6
The ADC-T Data Logger....................... page 7
Programming Examples......................... page 7
Voltage Reference Options for Sensors. page 8
Temperature Sensor Pin-Out................. page 8
Connection Diagram ADC-T8 & T12...... page 9

      

Temperature Sensor Calibration............. page 10
Sensor Options and Mounting................ page 10

SPECIFICATIONS

Power Supply.......................

Powered from USB port (5 volts DC)

Operating Temp. Range......

-40° C to +85° C

Serial Data Protocol.............   75 to 6,000,000 baud - auto detect (defaults to 115,200 baud)

Full duplex operation (data bits, parity, stop bits will auto detect)

Maximum Sampling Rate...... 100 samples per second or better

Temperature Range.............

-40F to 212F (-40C to 100C)
Optional extended range sensors -67F to 302F (-55C to 150C)

Resolution............................

1 degree (optional 1/4 degree resolution available)

Accuracy.............................

1 degree (when using the standard sensors)

Temperature Inputs............... Available in 4, 8 and 12 channel versions

ADC-T4

4 channel (4 temperature sensors included - TO-92)

ADC-T8

8 channel (8 temperature sensors included - TO-92)

ADC-T12

12 channel (12 temperature sensors included - TO-92)

Software Compatibility.........

Windows XP, Vista, Windows Server, Windows 7, Windows 8.1 and Windows 10

Weight.................................

.5 ounce

Size......................................

1.875 inches by 2.5 inches  

ADC-T4

1.875 inches by 3.125 inches  ADC-T8
1.875 inches by 3.75 inches    ADC-T12

Page 1

Expansion Capability............

expandable to control up to 144 relays/inputs (or combinations) using 
EX-8M, EXM-8, EXM-16 or EXM-32 Relay I/O Expansion Modules

Interface.............................. 

USB (also available in WiFi version (ADCT-WIFI), Ethernet version 
(ADCT-ENET) RS-232 version (ADCT-RS232) or 
RS-485 version (ADCT-RS485))

  

TECHNICAL REFERENCE

ADC-T SERIES

TEMPERATURE 

INTERFACE

Click for more info:     www.eeci.com/adc-tp.htm

(937) 349-6000
(800) 842-7714
(937) 349-6000
[email protected]

PHONE...................
ORDERS................
TECH SUPPORT...
E-mail.....................

www.eeci.com

  

4, 8 and 12 channel

Summary of Contents for ADC-T Series

Page 1: ...d range sensors 67F to 302F 55C to 150C Resolution 1 degree optional 1 4 degree resolution available Accuracy 1 degree when using the standard sensors Temperature Inputs Available in 4 8 and 12 channe...

Page 2: ...nager The entry should disappear and then reappear when you plug the ADC T back in If you do not have an Internet connection or are having problems with the USB Com driver installation disconnect the...

Page 3: ...ADC T Analog to Digital Converter to the same USB port and install the ADC T device driver by clicking the Install EECI Device Driver button from the installer dialog window if you have auto start dis...

Page 4: ...t shown The com port may be changed by clicking the Setup button and changing the com number in the Com Port window and clicking Apply Clicking the Setup button allows you to label the temperature inp...

Page 5: ...ion 4 5 volt allows a 0 to 5 volt input range or 2 5 to 2 5 volts in differential mode with reference 3 channel single ended reference voltage from AUX header is applied to the channel 4 analog input...

Page 6: ...f 0 volts at 0 degree K This is how the offset of 459 degrees is obtained since degrees K is 459 less then degrees F or 273 degrees less then degrees C The scale is determined by dividing the 4 096 vo...

Page 7: ...idge Rd Milford Center OH 43045 9016 USA 937 349 6000 800 842 7714 937 349 6000 sales eeci com https www eeci com PHONE ORDERS TECH SUPPORT E mail Web International Domestic Copyright 2014 2021 Electr...

Reviews: