Logic interface description
Type
Open collector transistor plus pull up
resistor.
< Normal speed (default 80%)
OFF (4.7 k pull up + diode to 12 V d.c.)
³
Normal speed
ON (< 0.8 V d.c. sinking 10 mA)
Maximum current rating
10 mA
Maximum voltage rating
28.8 V d.c.
FAIL status output:
Type
Open collector transistor plus pull up
resistor.
Fail
OFF (4.7 k pull up + diode to 12 V d.c.)
OK
ON (< 0.8 V d.c. sinking 10 mA)
Maximum current rating
10 mA
Maximum voltage rating
28.8 V d.c.
Analogue 10 V reference
+ 10 V d.c. analogue voltage reference
Unipolar output with diode protection
Voltage accuracy
± 2% full scale
Output current
£
5 mA for specified accuracy
* Mating half of connector not supplied.
Table 12
Logic interface connector pins
Pin
Number
Signal
Polarity Use
1
Analogue Speed
Enable
‑
control Input
-
Connect to Pin 2 (0 V) to enable
analogue speed control via Pin 9.
2
0 V Control Reference
-
0 V reference for ALL control and status
signals listed within this table.
3
START / STOP - Control
Input
-
Connect to Pin 2 (0 V) to START the
nXDS pump system.
4
STANDBY - Control
Input /
Serial-RX/RS485 A-
-
Connect to Pin 2 (0 V) to enable
STANDBY speed when the SERIAL
ENABLE control input is inactive.
5
Serial Enable - Control
Input
-
Connect to Pin 2 (0 V) to enable serial
communications.
6
RS232/RS485 - Control
Input
-
Default configuration is RS232 with Pin
6 unconnected.
Connect to Pin 2 (0 V) to enable RS485
serial communications.
7
FAIL
‑
Status Output/
Serial
‑
TX/RS485 B+
-
Logic HIGH when a fail or fault
condition exists and the SERIAL ENABLE
control input is inactive.
8
0 V Control Reference
-
0 V reference for all control and status
signals listed within this table.