Edwards MN-NETSW1 Quick Start Manual Download Page 4

Page 4 of 4

 

  D A T A   S H E E T

 E85010-0144

 

Not to be used for installation purposes.

  Issue 1.1

04-04-20

LIFE SAFETY & INCIDENT MANAGEMENT

Contact us

Phone:   800-655-4497 (Option 4) 
Email:  

[email protected]

   

Website:  

edwardsfiresafety.com

8985 Town Center Pkwy 
Bradenton, FL 34202

© 2020 Carrier 
All rights reserved.

Ordering Information

MN-COM1S

UL 864 Listed FireWorks Communications Ethernet Port, Command & 
Control.  Comes with power and RS232 data cables

MN-NETSW1

Four-port multimode fiber optic Ethernet switch

Related Equipment

MN-BRKT1

MN-FVP mounting bracket for EST3 enclosures

MN-BRKT3

MN-FVP mounting bracket for APS-(6)(10)A power supplies

FW-NCCA4

Ethernet cable conduit connector assembly for UL4 computer

MN-FVPB1

Polymer mounting bracket for MN-FVPN 

MN-FVPN

Fire VoIP encoder/decoder, includes power and audio cables

MN-PASM2

MN-FVPN preamp signal supervisory booster module (1 required per MN-
FVPN, along with SIGA-RM1 or SIGA-MRM1)

SIGA -RM1/MRM1

Riser Supervision Module

MN-ABPM

Audio Bridge (Panel mount 3-ATPINT)

Specifications, MN-NETSW1

Voltage

18 to 28 VDC

Current

350 mA, max.

Dimensions (W × H × D)

1.75 × 7.54 × 5.54 in.   
(44 x 191 × 138.4 mm)

Fiber optic ports 
 Quantity 
 

Connector type 

 

Signaling /Data Rate 

 Attenuation

 

ST 
100Base-FX / 100 Mbps 
13 db, max. at a 1310 wave length

Operating environment 
 Temperature 
 Humidity

 
32 to 120°F (0 to 49°C) 
0 to 93% RH, noncondensing at 90°F/32°C

Segment Length

Copper

Fiber Optic

Fiber Optic Budget

3,28ft (100m) 

~6,562 ft (2km) multi mode fiber 

10dB

Segment Media

Copper

Fiber Optic (1300 nm)

Category 6 UTP

50/125 or 62/5/125 Multi Mode Fiber

Agency Listings

CE; FCC Part 15, Class A; EN50081-2; EN50082-2; UL-864

Power Requirements

24VDC at 21 mA, nominal10 –36VDC, 5 watts 8-24VAC, 47 – 63 

Hz, 5 VA

Specifications, MN-COM1S

Voltage

18 to 28 VDC

Current

60 mA

Dimensions

(W × H × D) 2.5 × 0.9 × 3.5 in. (6.4 × 2.3 × 9.0 cm)

Serial interface

RS-232C

Network Interface
    Connector
    Cable type
    Other

 
RJ-45
Category 5, min.
10/100 Mbps, TCP/IP, autonegotiating 

Operating environment
    Temperature
    Humidity

 
32 to 120°F (0 to 49°C) 
0 to 93% RH, noncondensing at 90°F (32°C) 

Summary of Contents for MN-NETSW1

Page 1: ...mass notification settings to connect a FireWorks workstation to an EST3 control panel Both the MN NETSW1 and the MN COM1S mount on an MN BRKT1 or an MN BRKT3 bracket These install inside the EST3 control panel or Auxiliary Power Supply for a neat and self con tained mass notification solution Standard Features MN NETSW1 Four port Mass Notification Ethernet Switch Connect alarm panels to a remote ...

Page 2: ...nt on an MN BRKT1 or an MN BRKT3 bracket These install inside the EST3 control panel or Auxiliary Power Supply for a neat and self contained mass notification solution MN NETSW1 MN BRKT1 MN COM1S MN BRKT3 MN NETSW1 MN COM1S EST3 Control Panel Component Layout MN BRKT1 Mounting Bracket APS Auxiliary Power Supply MN BRKT3 Mounting Bracket ...

Page 3: ...nduit and attach the conduit to the FireWorks computer using the required conduit adapter Use the control panel power supply or a compatible regulated 24 VDC power supply that is UL ULC listed for fire protective signal ing systems Wiring WARNING This is a Class A product In a domestic environment the product may cause radio interference in which case the user may be required to take adequate meas...

Page 4: ... or SIGA MRM1 SIGA RM1 MRM1 Riser Supervision Module MN ABPM Audio Bridge Panel mount 3 ATPINT Specifications MN NETSW1 Voltage 18 to 28 VDC Current 350 mA max Dimensions W H D 1 75 7 54 5 54 in 44 x 191 138 4 mm Fiber optic ports Quantity Connector type Signaling Data Rate Attenuation 2 ST 100Base FX 100 Mbps 13 db max at a 1310 wave length Operating environment Temperature Humidity 32 to 120 F 0...

Reviews: