6.2.1 Shut down modes
▪
Auto shut down introduces a nitrogen purge cycle which lasts for 15
~
90 minutes
before the pump is shut down. This is the recommended shut down mode.
▪
Fast shut down immediately stops the pump without gas purge.
▪
Ramped shut down is an optional mode for this system. In some harsh
applications, process residues can accumulate in the pump mechanism during shut
down and will make it difficult to restart the pump next time. To prevent this
problem a special ramped shut down can be performed. Contact your supplier for
more information.
6.2.2 Shut down through a MicroTIM
Use your control equipment to reset the pump start/stop signal to the interface
connector. The Running LEDs will then go off, and the pump running status output signal
will open.
6.2.3 Shut down through a PDT
1.
Press the Stop button on the PDT. Refer to
for more
information.
2.
Select 'Auto' or 'Fast shut down' mode.
6.2.4 Shut down through the front panel control
1.
Press and hold the STOP button (
) for 5 seconds to stop
the pump in 'Auto shut down' mode (recommended, refer to
page 63).
2.
Repeat in 10 seconds to stop the pump in 'Fast shut down' mode. The running LED
flashes while the pump slows down and will then turn off when the pump has shut
down.
6.2.5 Controlled stop
WARNING: HOT SURFACES
Risk of burn injury. For TX variants the exhaust heaters will remain powered on even
when the emergency stop is activated.
Note:
The controlled stop switch is not an electrical isolator.
To shut down the system in an emergency, press the EMS button (
). Alternatively, the controlled stop controls can be operated in the customer’s
own control system if the controlled stop circuit is connected to the system as described
in
Connect to the emergency stop circuit
on page 45.
When controlled stop is selected:
▪
The dry pump and/or the booster pump is switched off.
10/2020 - ©Edwards Limited
Page 63
M56635880_D
M56635880_D - Operation
Summary of Contents for iXM Series
Page 1: ...Dry Pump System iXM INSTRUCTION MANUAL M56635880_D Original instructions edwardsvacuum com...
Page 101: ...This page has been intentionally left blank...
Page 102: ...This page has been intentionally left blank...
Page 103: ...This page has been intentionally left blank...
Page 104: ...edwardsvacuum com...