TECHNICAL DATA
2.3
Cooling system
Table 1 - Motor Supply Current (A)±5%
Motor supply current (A)
Pump
Supply
Pump inlet at
ultimate
vacuum
Pump inlet at
atmospheric
pressure
Rated full load
current for
continuous
motor
operation
Locked rotor
condition
GV260
50 Hz 415v
11
18
20.8
173
GV260
60 Hz 460v
11
22
22.9
142
GV410
50 Hz 415 V
17
23
28.1
219
GV410
60 Hz 460 V
15
26
28.4
199
GV600
50 Hz 415 V
17
41
39.5
324
GV600
60 Hz 460 V
16
44*
33.8
216
* Motors carry S2 ratings that enable them to run safely with this current when the pump is subjected to high
inlet pressures. Supply protection circuit breakers should be set at this level as described in
Cooling system type
Direct water-cooling
Cooling-water requirements
See
Thermal snap-switches
Warning thermal snap-switch
Opening temperature
154°F (68°C)
Closing temperature
144°F (62°C)
Shutdown thermal snap-switch
Opening temperature
167°F (75°C)
Closing temperature
147°F (64°C)
Contact ratings
Maximum voltage
240 V
Maximum load (inductive)
120 VA
Maximum current (resistive load)
12 A
Table 2 - Technical Data
Pump Type
DATA
GV260 50
Hz
GV260 60
Hz
GV410 50
Hz
GV410 60
Hz
GV600 50
Hz
GV600 60
Hz
Mass: kg
767
785
819
848
1022
959
Continuous power
11 kW
20 hp
15 kW
25 hp
22 kW
30 hp
Noise: dB (A *)
<76
<78
<76
<78
<76
<78
Max. pumping speed: m
3
h
-1
240
320
380
460
560
540
Displacement: m
3
h
-1
336
405
526
635
793
727
Ultimate: mbar
<0.065
<0.04
<0.065
<0.04
<0.05
<0.04
Maximum heat removed: kW
7.0
8.0
10.0
13.2
14.5
16.5
Maximum coolant flow: l/min
5.0
5.0
5.6
9.0
4.5
5.5