3.7
Locate the pump
Ensure that the operating location is clean and free from debris and oil.
You must ensure that when the pump is in its required operating location, all of the mounting feet are in the same
plane, flat on the mounting platform. The platform must be firm and level, with a maximum flatness deviation less
than that specified in
Do
not
use shims or spacers under the mounting feet to level the pump.
1. Use slings around the bearing housings or casing flanges (refer to the System Manual) to connect suitable lifting
equipment to the pump.
2. Use the lifting equipment to move the pump to its required operating location on the mounting platform, then
disconnect the lifting equipment.
3. Fit suitable bolts through the fixing bolt holes in the mounting feet, to secure the pump in position. Refer to the
System Manual for the locations and sizes of the fixing holes.
3.8
Fit the motor or drive/transmission
3.8.1
Introduction
The pump is supplied as a bareshaft pump. You must therefore fit a suitable motor (refer to
), or fit a
suitable drive and transmission (refer to
).
3.8.2
Fit a motor
Fit your motor to the pump as specified in the manufacturer’s manual supplied with your motor. Ensure that the
motor is suitable for use with the pump.
WARNING
Use suitable lifting equipment to move the pump, as described below. If you do not, you can injure
yourself or damage the pump. Refer to the System Manual for the mass of the pump.
WARNING
On ATEX Category 1, 2 and 3 pumps, your motor must comply with the requirements of the ATEX
Directive (94/9/EC). If it does not, the external ATEX certification will not be valid.