Return the equipment or components for service

  

 

Before you send your equipment to us for service or for any other reason, you must send us a 
completed Declaration of Contamination of Vacuum Equipment and Components – Form HS2. The 

HS2 form tells us if any substances found in the equipment are hazardous, which is important for 
the safety of our employees and all other people involved in the service of your equipment. The 

hazard information also lets us select the correct procedures to service your equipment.  
 
We provide instructions for completing the form in the Declaration of Contamination of Vacuum 

equipment and Components – Procedure HS1.  
 

If you are returning a vacuum pump, note the following:  
 

 

If a pump is configured to suit the application, make a record of the configuration before 
returning the pump. All replacement pumps will be supplied with default factory settings.   

 

Do not return a pump with accessories fitted. Remove all accessories and retain them for 
future use.  

 

The instruction in the returns procedure to drain all fluids does not apply to the lubricant in 
pump oil reservoirs.   

 
Download the latest documents from 

www.edwardsvacuum.com/HSForms/

, follow the procedure in 

HS1, fill in the electronic HS2 form, print it, sign it, and return the signed copy to Edwards.  

 

Note

:  

If we do not receive a completed HS2 form, we will not accept the return of the 

equipment.

  

 

 

P80081000, Issue

 A 

Summary of Contents for A726-01-805

Page 1: ...A726 01 840 Issue F Original Instruction Manual XDS Replacement Tip Seal and Exhaust Valve Kit Description Item Number XDS5 10 Replacement Tip Seal Kit A726 01 805...

Page 2: ......

Page 3: ...t valve 1 For return of equipment complete the HS Forms at the end of this manual Illustrations Figure Page 1 Replacing the tip seals pre serial number 037874870 XDS5 or 037869927 XDS10 3 2 Replacing...

Page 4: ...This page has been intentionally left blank A726 01 840 Issue F Page ii Edwards Limited 2010 All rights reserved Edwards and the Edwards logo are trademarks of Edwards Limited...

Page 5: ...XDS pumps post serial number 037874870 XDS5 or 037869927 XDS10 continue at Step 9 4 The exhaust duct 105 is now exposed on the outside of the fixed scroll If the pump is an XDS C remove the 5 screws 1...

Page 6: ...centre of the scroll fit it into the slot in the orbiting scroll This tip seal is longer than required so must be cut to the correct length There should be a gap of 20 mm between the end of the tip s...

Page 7: ...ghts reserved Page 3 Edwards and the Edwards logo are trademarks of Edwards Limited Replace the tip seals and exhaust valve A726 01 840 Issue F Figure 1 Replacing the tip seals pre serial number 03787...

Page 8: ...dwards Limited 2010 All rights reserved Edwards and the Edwards logo are trademarks of Edwards Limited Replace the tip seals and exhaust valve Figure 2 Replacing the tip seals post serial number 03787...

Page 9: ...imited 2010 All rights reserved Page 5 Edwards and the Edwards logo are trademarks of Edwards Limited Replace the tip seals and exhaust valve A726 01 840 Issue F Figure 3 XDS5 10 pump side view 1 Leve...

Page 10: ...A726 01 840 Issue F Page 6 Edwards Limited 2010 All rights reserved Edwards and the Edwards logo are trademarks of Edwards Limited This page has been intentionally left blank...

Page 11: ...of Vacuum equipment and Components Procedure HS1 If you are returning a vacuum pump note the following If a pump is configured to suit the application make a record of the configuration before return...

Page 12: ...P800 80 000 Issue T edwardsvacuum com...

Reviews: