Edwards Oil Level Monitor 

Description

Item Number

OLM100

A504-33-000

Summary of Contents for A504-33-000

Page 1: ...A504 33 880 Issue C Original Instruction Manual Edwards Oil Level Monitor Description Item Number OLM100 A504 33 000...

Page 2: ...This page has been intentionally left blank...

Page 3: ...RIPTION 1 2 TECHNICAL DATA 3 3 INSTALLATION 5 4 MAINTENANCE 9 RETURN OF EDWARDS EQUIPMENT Illustrations Figure Page 1 Edwards Oil Level Monitor type OLM100 fitted to rotary vane pump 1 2 Cross section...

Page 4: ...This page has been intentionally left blank A504 33 880 Issue C Page ii Edwards Limited 2009 All rights reserved Edwards and the Edwards logo are trademarks of Edwards Limited...

Page 5: ...visible alarms Alarms not supplied To fit simply drain the pump of oil remove the existing sight glass and bezel and fit the new OLM100 Replace the original sight glass and bezel and refill the pump...

Page 6: ...A504 33 880 Issue C Page 2 Edwards Limited 2009 All rights reserved Edwards and the Edwards logo are trademarks of Edwards Limited This page has been intentionally left blank...

Page 7: ...A A504 33 880 Issue C 2 TECHNICAL DATA Production Description Ordering Number OLM100 oil level monitor fits E1M40 E2M40 E1M80 and E2M80 rotary vane pumps A504 33 000 Electricity rating Operating volta...

Page 8: ...A504 33 880 Issue C Page 4 Edwards Limited 2009 All rights reserved Edwards and the Edwards logo are trademarks of Edwards Limited This page has been intentionally left blank...

Page 9: ...tion the oil level monitor assembly on the oil box and carefully start tightening all four cap screws 12 Fit the four remaining cap screws and shakeproof washers Lightly tighten in a diagonal and prog...

Page 10: ...se are not interchangeable as one locates onto the lug with the tab on the pin cover Note The tab at both ends of one pin cover must align with the red dot on the plug body 21 Carefully slide in pin a...

Page 11: ...Edwards and the Edwards logo are trademarks of Edwards Limited INSTALLATION A504 33 880 Issue C Figure 3 Oil Level Monitor component parts 1 Housing 5 Socket 3 way 2 Ball 6 Plug 3 way 3 Float switch...

Page 12: ...ted This page has been intentionally left blank Figure 4 Oil Level Monitor electrical connections A Wiring diagram 24 V ac dc 1 24 V ac dc B View on pin side of socket 2 Earth top connector C View sho...

Page 13: ...re trademarks of Edwards Limited MAINTENANCE A504 33 880 Issue C 4 MAINTENANCE The Oil Level Monitor requires no specific maintenance other than a regular check to ensure that the seal in not leaking...

Page 14: ...A504 33 880 Issue C Page 10 Edwards Limited 2009 All rights reserved Edwards and the Edwards logo are trademarks of Edwards Limited This page has been intentionally left blank...

Page 15: ...This page has been intentionally left blank...

Page 16: ...This page has been intentionally left blank...

Page 17: ...contaminated equipment may not be suitable for airfreight PROCEDURE 1 Contact Edwards and obtain a Return Authorisation Number for your equipment 2 Complete the Return of Edwards Equipment Declaration...

Page 18: ...ACT EDWARDS FOR ADVICE BEFORE YOU RETURN SUCH EQUIPMENT Print your name _________________________________ Print your job title ____________________________________ Print your organisation ____________...

Page 19: ...This page has been intentionally left blank...

Page 20: ...0 Sint Pieters Leeuw Brussels Tel 32 2 363 0030 Fax 32 2 363 0064 INDIA 203 Surya Kiran Building 19 Kasturba Gandhi Marg New Delhi 110 001 India Tel 91 11 4151 0065 Fax 91 11 4151 0245 ISRAEL 5 Habarz...

Reviews: