2.5 Electrical data
Table 7
Electrical data
Characteristics
GXS160 GXS160/1750 GXS250 GXS250/2600
GXS450
Units
Dry pump motor rating
7.5
7.5
7.5
7.5
11
kW
Mechanical booster
motor rating
-
4.5
-
7.5
-
kW
Current rating
(200 - 230 V systems)
25
31
31
38
49
A
Current rating
(380 - 460 V systems)
11
14
14
20
26
A
Recommended branch
circuit protection UL
(200 - 230 V systems)
30
40
40
50
60
A
Recommended branch
circuit protection IEC
(200 - 230 V systems)
25
35
35
35
50
A
Recommended branch
circuit protection UL
(380 - 460 V systems)
15
20
20
25
30
A
Recommended branch
circuit protection IEC
(380 - 460 V systems)
15
15
15
20
30
A
Min cable size for 200 -
230 V systems (or
corresponding AWG size)
6 (8)*
6 (8)*
6 (8)*
10 (8)
10 (6)
mm
2
(AWG)
Min cable size for 380 -
460 V systems (or
corresponding AWG size)
6 (8)*
6 (8)*
6 (8)*
6 (8)*
6 (8)*
mm
2
(AWG)
Mains connector for 200 -
230 V systems
Han
®
K
4/4
Han
®
K 4/4
Han
®
K
4/4
Han
®
K 4/4
Han
®
K 4/4
-
Mains connector for 380 -
460 V systems
Han
®
K
4/4
Han
®
K 4/4
Han
®
K
4/4
Han
®
K 4/4
Han
®
K 4/4
-
Page 20
M58800880_H - Technical data
Summary of Contents for 9773512584
Page 6: ...This page has been intentionally left blank ...
Page 87: ...Figure 19 GXS160 installation drawing Sheet 4 Page 83 M58800880_H Installation drawings ...
Page 178: ...This page has been intentionally left blank ...
Page 179: ...This page has been intentionally left blank ...
Page 180: ...edwardsvacuum com ...