Materials needed: 
 

 

900-260 Anemometer Sensor 

 

900-215 Battery 

 

Materials needed to configure your offline 
experiment: 
 

 

900-213  Module  or  900-268  module  or  900-272 
Module 

 

USB  to  mini  USB  cable  (included  with  the  900-
213 module). 

 

Procedure: 

 
1.

 

Connect  the  anemometer  sensor  directly  to  the 
left side of a charged 900-215 module. 

2.

 

When ready to collect data press the “Start/Stop” 
button on the anemometer sensor, a red light will 
turn on for the duration of the experiment. 

3.

 

To change the experiment settings first connect to 
your  chosen  device  (PC,  Mac,  tablet,  smart 
device)  and  select  the  “Module  setup”  button.  
(For  more  information  on  how  to  change  the 
experiment  settings  view  quick  start  procedure 
section for your chosen device in this document.) 

4.

 

After  the  experiment  has  concluded  (when  the 
“Start/Stop”  button  is  pressed  again  or  the  data 
collection period ends) connect the sensor to your 
chosen device. (full instructions in each device’s 
quick start procedure section) 

5.

 

Open Edu-Logger software. 

6.

 

Click the “Off-line experiment” button. 

7.

 

Click the “Load data from sensors” button.  

8.

 

Select  which  experimental  data  to  upload.  (5 
experimental  runs  can  be  stored  at  one  time  on 
the 900-260 anemometer sensor) 

 

Summary of Contents for 900-260

Page 1: ...Edu Logger Anemometer Logger Sensor Guide 900 260 ...

Page 2: ...e sensor comes pre calibrated so you can start experimentation right out of the box using this guide Hundreds of possible experimental subjects that can be done with the 900 260 sensors are weather studies photosynthesis rates animal behavior insect flight and many more The anemometer sensor uses the following units of measure Kilometers per hour km hr An SI measurement of velocity Miles per hour ...

Page 3: ...er guide Note Make sure not to download and install both types of software they will conflict on the computer Procedure 1 Install the Edu Logger software 2 Connect the 900 213 module to the PC or Mac 3 Connect the anemometer sensor to the 900 213 module they directly plug together Please note there is no calibration required for this sensor 4 Open the Edu Logger software 5 Once a anemometer sensor...

Page 4: ...rials needed 900 260 Anemometer Sensor 900 268 WiFi module 900 215 Battery Your anemometer sensor needs to be connected to a 900 268 module The 900 268 module will create a closed Edu Logger WiFi network which will stream the Edu Logger data to a device of your choosing Once your device is wirelessly connected to the Edu Logger network you can run experiments and collect data through a browser of ...

Page 5: ... Module ID found on the back of the 900 268 device Edu LoggerXXXX for example 8 Give your device about 20 seconds to connect to the 900 268 9 Once the device is connected go to your browser and type the website wifi201 com into the URL bar then wait for 30 60 seconds 10 You will see a Control mode icon in the browser click on this icon 11 The browser will then load a new screen and begin to auto d...

Page 6: ...ll return the unit to WiFi mode Operation with Edu Logger viewer Materials needed 900 260 Anemometer Sensor 900 272 Viewing Module 900 215 Battery Procedure 1 Connect the anemometer sensor to the left side of the viewer 2 Connect the 900 215 module to the right side of the viewer 3 The 900 272 will auto detect the sensor and you will see it appear on the left side of the screen 4 Once the sensor a...

Page 7: ...ings first connect to your chosen device PC Mac tablet smart device and select the Module setup button For more information on how to change the experiment settings view quick start procedure section for your chosen device in this document 4 After the experiment has concluded when the Start Stop button is pressed again or the data collection period ends connect the sensor to your chosen device ful...

Page 8: ...ey directly plug together Please note there is no calibration required for this sensor 3 Open the Edu Logger software 4 Click the Tools icon 5 Click the Restore sensor s factory defaults on the menu 6 If prompted to clear the graph click either the Off line experiment or On line experiment whichever you are using 7 Click Clear experiment results 8 Resume from step 4 ...

Page 9: ...ation modes 0 to 75 mph 0 to 120 km hr ADC resolution 15 bit Resolution 0 01 mph 0 01 km hr Max sample rate S sec 100 Sensor features Fully digital data Rugged plastic ergonomic case Durable anemometer probe attached by a strong rubber coated wire Push button switch for Start Stop experiments in off line mode LED indicator of experiment status blinks while collecting data Pre calibrated sensing eq...

Page 10: ...r example The sensor is pre calibrated at the factory The built in software in the logger can be upgraded at any time using software Inside of the anemometer sensor a magnet is situated within a metal coil The magnet is connected directly to the wind speed detector which causes the magnet to spin with the same velocity as the wind propelling it The shaft is installed in a bearing and has a magnet ...

Page 11: ...the anemometer sensor Store in a box at room temperature out of direct sunlight Warranty We promise to deliver our sensor free of defects in materials and workmanship for a period of 3 years from the date of purchase Our warranty does not cover damage of the product caused by improper use abuse or incorrect storage Sensors with a shelf life such as ion selective proves have a warranty of 1 year Sh...

Page 12: ...12 Thank you for using Edu Logger W www edulab com E info edulab com V10202013 ...

Reviews: