7.

 

Click  the  “On-line  experiment”  button;  this  will 
open a graph below. 

8.

 

Click  on  the  “Module  setup”  button  located  on 
the pressure sensor icon in the module window to 
change the sensor settings if need be. 

9.

 

Click on the "experiment set up" button to change 
the  experiment  settings  if  need  be  (experiment 
duration for example). 

10.

 

The pressure sensor will give a live reading in the 
box to the left of the screen while plugged in. 

11.

 

To run an experiment and collect data click “Run 
experiment”. 

12.

 

To  end  data  collection  early,  click  “Stop 
experiment”. 

 
 

Tablet, smart phone device 

 

Materials needed: 
 

 

900-210 Pressure Sensor 

 

900-268 WiFi module 

 

900-215 Battery 

 
Your pressure sensor needs to be connected to a  900-
268 module. The 900-268 module will create a closed 
Edu-Logger WiFi network which will stream the Edu-
Logger  data  to  a  device  of  your  choosing.  Once  your 
device  is  wirelessly  connected  to  the  Edu-Logger 
network  you  can  run  experiments  and  collect  data 
through a browser of your choosing. 
 

Procedure: 

 
1.

 

Connect  the  pressure  sensor  directly  to  the  left 
side of a 900-268 module (no wires required). 

2.

 

Connect a 900-215 module to the right side of the 
900-268 module. 

Summary of Contents for 900-210

Page 1: ...Edu Logger Pressure Logger Sensor Guide 900 210 Edu Logger pressure logger sensor 900 210 ...

Page 2: ... the open or in large containers A hose with an attachment piece come connected to the sensor to make connections to various mediums easier Hundreds of possible experiments that can be done with the 900 210 sensors are Boyle s Law Gay Lussac s Law for ideal gases weather phenomena yeast and microbe fermentation small animal exercise physiology chemical reactions and many more The pressure sensor i...

Page 3: ...b com as well as a full software user guide Note Make sure not to download and install both types of software they will conflict on the computer Procedure 1 Install the Edu Logger software 2 Connect the 900 213 module to the PC or Mac 3 Connect the pressure sensor to the 900 213 module they directly plug together Please note there is no calibration required for this sensor 4 Open the Edu Logger so...

Page 4: ...xperiment 12 To end data collection early click Stop experiment Tablet smart phone device Materials needed 900 210 Pressure Sensor 900 268 WiFi module 900 215 Battery Your pressure sensor needs to be connected to a 900 268 module The 900 268 module will create a closed Edu Logger WiFi network which will stream the Edu Logger data to a device of your choosing Once your device is wirelessly connecte...

Page 5: ...mart phone go to the WiFi settings and select the Edu Logger network which matches the 900 268 Module ID found on the back of the 900 268 device Edu LoggerXXXX for example 8 Give your device about 20 seconds to connect to the 900 268 9 Once the device is connected go to your browser and type the website wifi201 com into the URL bar then wait for 30 60 seconds 10 You will see a Control mode icon in...

Page 6: ...68 To engage operation in this fashion press 3 times on the panel key Repeating this operation will return the unit to WiFi mode Operation with Edu Logger viewer Materials needed 900 210 Pressure Sensor 900 272 Viewing Module 900 215 Battery Procedure 1 Connect the pressure sensor to the left side of the viewer 2 Connect the 900 215 module to the right side of the viewer 3 The 900 272 will auto de...

Page 7: ...on the pressure sensor a red light will turn on for the duration of the experiment 3 To change the experiment s settings first connect to your chosen device PC Mac tablet smart device and select the Module setup button For more information on how to change experiment settings view the quick start procedure section for your chosen device in this document 4 After the experiment has concluded when th...

Page 8: ...art device 2 Connect the pressure sensor to a 900 213 module they directly plug together Please note there is no calibration required for this sensor 3 Open the Edu Logger software 4 Click the Tools icon 5 Click the Restore sensor s factory defaults on the menu 6 If prompted to clear the graph click either the Off line experiment or On line experiment whichever you are using 7 Click Clear experime...

Page 9: ...uracy 1 Resolution 0 01 0 1 0 1 0 01 Max sample rate S sec 100 Sensor features Fully digital data Rugged plastic ergonomic case Push button switch for Start Stop experiments in off line mode LED indicator of experiment status blinks while collecting data Pre calibrated internal sensing equipment Hose with attachment piece connected directly to the sensor body for easy connection to various mediums...

Page 10: ...c units o C o F Lux ppm for example The sensor is pre calibrated at the factory The built in software in the logger can be upgraded at any time using software The pressure sensor uses the piezoresistive effect The transducer is based on silicon between metal foils that changes its resistance according to pressure One side of it is at complete vacuum that enables to measure the absolute pressure on...

Page 11: ... to deliver our sensor free of defects in materials and workmanship The warranty is for a period of 3 years from the date of purchase and does not cover damage of the product caused by improper use abuse or incorrect storage Sensors with a shelf life such as ion selective probes have a warranty of 1 year Should you need to act upon the warranty please contact your distributor Your sensor will be r...

Page 12: ...12 Thank you for using Edu Logger Flexible simple fast forward thinking W www edulab com E info edulab com V10012013 ...

Reviews: