EDTM GLASS-CHEK+ GC2001 Manual Download Page 1

GENERAL DESCRIPTION:

The GLASS-CHEK+ measures the thick-

ness of both lites of glass, as well as the 

airspace of an insulating glass window as-

sembly. All thickness measurements can be 

obtained from a single side. Simply press 

the GLASS-CHEK+ meter against a single 

lite  of  glass,  or  a  double  pane  window, 

push the power button and hold it until the 

measurements are digitally displayed. The 

thickness of each lite of glass, the air space, 

and the overall thickness of the IG unit will 

simultaneously appear on the 2-line LCD 

display. On a separate results screen the 

meter will also indicate the presence and 

location of any Low-E coatings on the first 

pane of glass.

The GLASS-CHEK+ contains a single pane 

Low-E coating detector. The single lite Low-

E detector will test the nearest lite of glass 

in an IG unit. To fully analyze an IG unit re-

garding Low-E coatings, the window should 

be tested on both sides to confirm the pres-

ence or absence of the Low-E coating. If 

you only have access to one side of the 

window, we recommend upgrading to our 

Glass-Chek PRO (Model # GC3000).
The user may choose to have the thick-

ness  results  displayed  in  one  or  two  of 

the following options: fractions of an inch, 

thousandths of an inch, or millimeters. The 

results screen will flash between the differ-

ent thickness options selected by the user.

745 Capital Commons Drive

Toledo, Ohio  43615    USA

PHONE: (419) 861-1030

FAX: (419) 861-1031

www.EDTM.com     Email: [email protected]

GLASS-CHEK+

Glass and Air Space Thickness Meters

MODEL# GC2001

GLASS CHEK+ LOW-E DETECTOR

OPERATION

The GLASS-CHEK+ will automatically test 

each measured window for the presence 

and location of Low-E coatings on the first 

pane of glass. The meter will differentiate 

if the coating is on Surface 1 or Surface 2. It 

will also indicate if the first pane of glass is 

clear glass, meaning there are no Low-E 

coatings present on the glass. Remember 

that Low-E coatings are typically placed on 

surface 2 or 3 of a window. If you are not 

sure which side of the window was intended 

to have the Low-E coating, you may want 

to test both sides to ensure you have fully 

tested for the coating. If testing both sides 

of the window is not possible, you should 

consider our 

Glass-Chek PRO (Model# GC 

3000)

 that will test both sides of a double 

pane window from a single side for Low-E 

coatings.  

DISPLAY OPTIONS

The display of the GLASS-CHEK+ meter is

pre-programmed at the factory to offer six 

different  display  formats  for  the  results 

screen. The user can choose to have the 

thickness measurements displayed in: 

Fractions of an inch … with 1/32” resolution

1/8         1 /2         1/8  IN

TOTAL IG:            3/4  IN

Decimal inches … with 0.001” resolution

0.125    0.500    0.125  IN

TOTAL IG:         0.750  IN

Millimeters … with 0.1 mm resolution

3.0        12.5        3.0  MM

TOTAL IG:         18.5  MM

The user may choose to have any one of 

these units of measure displayed, or a com-

bination of two of them. If a single unit of 

measure is selected, the results screen will 

alternate back and forth between the thick-

ness  results  and  the  Low-E  test  results. 

If the user selects two units of measure, 

the  results  screen  will  alternate  between 

the first unit of measure for thickness, the 

Low-E results screen and then the second 

unit of measure selected. 
To change the display format, take a mea-

surement and continue to hold the button 

while  the  results  are  displayed  multiple 

times. After approximately 40 seconds, the 

screen will prompt you to enter set-up mode. 

FOUR OPTIMAL TEST LOCATIONS

FOR MOST ACCURATE RESULTS

Ÿ

 Hold the meter steady AND FLAT against 

  the glass during measurement.  

Ÿ

 The meter should be centered on one of

  the four edges of the window with the bot-

tom edge of the meter placed parallel to 

the edge of the window (please see the 

image to the left). This will minimize the 

effect of a concave window. As you move 

away from the edge of a window, many 

windows will bow inward (concave). Be-

cause the sensor runs parallel to the bot-

tom edge of the meter, it is important to 

place the bottom edge of the meter along 

one of the four edge locations as shown.

GLASS THICKNESS & AIR SPACE

MEASUREMENT

Simply  press  the  GLASS-CHEK+  meter 

against the single or dual lite window as-

sembly and push the button. Continue to 

hold the button and the measurement re-

sults will appear within two to five seconds 

depending on the application. Tinted glass

applications will typically take longer to mea-

sure, while standard clear windows usually 

result in the fastest measurement. Hold the 

meter steady during the measurement. The 

results will be displayed on the screen and 

will continually flash back and forth between 

thickness data and the Low-E location for 

the first pane of glass. For best accuracy 

please see the “FOUR OPTIMAL TEST 

LOCATIONS  FOR  MOST  ACCURATE 

RESULTS” section below. Windows often 

deflect inward or outward due to varying 

barometric pressures. The window will hold 

closest to its original designed specification 

along the edges and at the corners where 

the spacer bars hold the glass fixed. The 

thickness  sensing  area  of  the  GLASS-

CHEK+ meter is located along the bottom 

edge of the meter. Therefore the four test-

ing locations shown in Figure 1 below will 

yield the best results. 

We recommend tak-

ing multiple readings to verify your re-

sults.

 Whenever possible, ensure that the 

glass sample under test is clean and that 

the exit location (aperture) of the laser is 

clear of lint, dirt or other contaminants. The 

laser aperture is on the back side of the 

GLASS-CHEK+ enclosure.

WE STRONGLY RECOMMEND ONLY US-

ING COMPRESSED AIR TO CLEAN THE 

LASER APERTURE. However, if there are 

fingerprints or other smudge marks on 

the laser aperture window that cannot  be

removed in any other way, a lint-free cloth 

can be used to wipe off the smudges.

The GC2001 instrument can test the thick-

ness of installed windows from either indoors 

or outdoors. In most all applications it does 

not matter what is behind the window, as 

long as there is nothing touching the far side 

surface of the window. For testing windows 

in the factory or warehouse, make sure you 

are only testing one window at a time. If 

testing a stack of IG’s, you must move the 

unit you are testing away from the stack 

so  the  additional  panes  of  glass  are  not 

added to the measurement viewing area. If 

testing in a lab, be sure to move the glass 

off the table surface before testing.

KEEP THE COMPETITIVE 

EDGE WITH PRODUCTS 

FROM EDTM, INC.

glass & air space laser meters, 

tempered glass detectors, SHGC, 

solar, visible, & uv meters Low-

E type detectors, 4 point sheet 

resistance meters, tin side detec-

tors, self-clean coating detectors, 

sales  kits,  temperature  guns  & 

sales kit 

accessories.

Figure 1: Recommended placement of meter.

Follow the instructions on the screen to se-

lect the display option of choice. When the 

display option of choice appears, simply re-

lease the button. Your meter is now equipped 

to read in the display format you selected.

APPLICATIONS

WILL TEST …

The GC2001 instrument is calibrated and 

designed for testing flat glass applications. 

It will test both single pane and double pane 

windows. The glass can be clear glass or 

coated with Low-E coatings, self clean coat-

ings or other specialty coatings as long as 

the glass/coating is transparent. The GC 

2001 will also measure tinted glass as long 

as it has a visible light transmission value 

of approximately 35% or above.  

WON’T TEST …

The GC2001 is not capable of measuring 

triple pane windows or glass that is coated 

with  reflective  (mirror-like)  coatings.  The 

GLASS-CHEK+ is also not capable of test-

ing  suspended  film  applications  such  as 

Heat Mirror. Laminated glass with Low-E 

coatings  positioned  against  the  laminate 

can also NOT be measured. 

For most of 

these applications we recommend our 

Glass-Chek PRO (Model# GC3000).

LAMINATED GLASS:

The  GC2001  will  test  regular  laminated 

glass assemblies. It will measure the 

over-

all thickness

 of the laminated assembly, as

long as there is no Low-E coating placed 

against the laminate inner-layer. The lami-

nate assembly can be a single piece or com-

bined into an insulating unit. The GC2001 

will NOT measure the PVB inner-layer or 

the individual pieces of glass making up the 

laminated glass, it will only measure the 

overall thickness of the laminated glass.

TRIPLE PANE & SUSPENDED FILM

The GC2001 will not attempt to measure 

triple pane windows. The user must pur-

chase the Glass-Chek PRO (#GC3000) for 

this application.

HIGH/LOW RESOLUTION … SPEED OF 

MEASUREMENTS

The GC2001 has been equipped with a High 

Resolution and Low Resolution Mode. The 

meter is shipped in Low Resolution Mode as 

this allows for the quickest measurements 

to be taken. The quicker measurements 

come at the expense of a little accuracy. 

If extreme accuracy is not important, then 

the low resolution mode is perfect for get-

ting the quickest test results possible. 
If you are testing glass for an application that 

requires higher accuracy, you can switch the 

meter into High Resolution Mode. This will 

improve the meters accuracy as stated in 

the specification section of this manual. The 

improved accuracy will cause the meter to 

take measurements more slowly. To change 

the resolution/speed of the meter, take a 

LOW-E ON

SURFACE 1

LOW-E ON

SURFACE 2

CLEAR 

GLASS

Low-E Coated

Surface

(

'

PANE 1 

AIR SP

ACE

PANE 2 

PANE 1 

AIR SP

ACE

PANE 2 

PANE 1 

AIR SP

ACE

PANE 2 

©  Copyright 2012 Electronic Design to Market, Inc.  All rights reserved.

1

Summary of Contents for GLASS-CHEK+ GC2001

Page 1: ...rthbetween thickness data and the Low E location for the first pane of glass For best accuracy please see the FOUR OPTIMAL TEST LOCATIONS FOR MOST ACCURATE RESULTS section below Windows often deflect...

Page 2: ...readings The GLASS CHEK will record accurate readings up to the point the elec tronics reach the outside temperature which is below the operating range Depending on the degree of cold ness this will a...

Page 3: ...ion de l application Les mesures avec du verre teint sont g n ra lement plus longues alors que les fen tres transparentes permettent de r aliser des mesures tr s rapidement Maintenez le me sureur sans...

Page 4: ...du vitrage et que vous effectuez le test un em placement optimal d taill la page 3 2 Nettoyez la surface du verre ou d placez l instrument vers une zone plus propre du vitrage 3 Retirez les particules...

Page 5: ...n dung innerhalb von zwei bis f nf Sekunden angezeigt Bei get nten Scheiben dauert die Messung in der Regel l nger als bei standardm igen Klarglasfenstern Halten Sie das Messger t w hrend der Messung...

Page 6: ...Fehlermel dung angezeigt die Sie darauf hinweist die Batterie umgehend auszutauschen Wenn dieses Niveau erreicht ist kann das Ger t keine Messungen durchf hren KORREKTURMASSNAHMEN 1 Stellen Sie sicher...

Page 7: ...o del uso Ven tanas de vidrio te idos demoran t picamen te m s tiempo en la medida y las ventanas claras est ndares generalmente dan una medida m s r pida Mantiene el medidor inm vil durante la medida...

Page 8: ...obando en la rea ptima de la prueba descrita en la p gina 7 2 Limpie la superficie de vidrio o mu vase a un rea m s limpia 3 Quite las part culas de polvo del rea de la abertura del l ser en la parte...