Valve Assemblies & The Valve Seats: 

The sealing of the flapper valves are what makes the diaphragm

pump work. If the valves are not sealing properly, the pump will not be performing to full potential

or may not be pumping at all. The valves tend to last longer than the diaphragm. When you

change the diaphragm inspect the valves for cracks and delamination and the valve seats for

pitting and any build up that will prevent the valve rubber from sealing effectively

. Testing the

pump is the best way to evaluate performance.

l

Change the valve assemblies as required.

l

Inspection and testing on a regular bases is recommended. For continuous duty application,

inspect the pump daily until a life pattern is established.

l

See Pump Performance Tests .

P-220A-03

Page 9 Maintenance

   Trouble Shooting

2.Problem

Air Cylinder is not going

up and down.

Possible Causes

a. Air pressure is low.

b. Discharge or suction line is

blocked.

c. Air cylinder is malfunctioning.

Action

If the cause is not obvious, isolate the source.

Check air line for pressue and flow. If ok, discon-

nect the inlet and discharge plumbing from the

pump and restart the pump. If pump cycles without

the plumbing connected, there could be a clog in

the lines. The back pressure caused by a com-

plete blockage in the inlet and discharge line  will

stop the pump. If the pump cylinder still does not

cycle then the problem is in the air cylinder. See

air cylinder section.

1.Problem

Pump is running, liquid

is not moving.

Possible Causes

a. Suction line is blocked.

b. Suction line has air leak

between liquid and inlet of the

pump.

c. Discharge and/or suction

valves are not working.

d. Diaphragm has a leak.

e. Discharge or suction line is

to high.

Action

If the cause is not obvious, isolate the source.

Disconnect the inlet and discharge plumbing from

the pump and perform the Manual Test. If the

cause is not in the pump check for a block or an

air leak in the suction line. Suction air leaks can

be cumulative and can be as simple as one or two

fittings not being sealed properly. Review Plumbing

The Edson Air Powered Diaphragm Pump is very simple and problems are usually isolated to the following components:

Suction and Discharge Plumbing

The Diaphragm and Valves

The Air Cylinder

Summary of Contents for 220A Series

Page 1: ...owered Diaphragm Base Mount Bronze 1 1 2 Inlet and 1 1 2 Discharge Make sure the pump received is the pump ordered Compare the pump with the packing list Make sure the parts list attached to this manu...

Page 2: ...0 Cycles Per Min 5 feet 1 5 m eters 1 foot 3 meters 10 feet 3 meters 17 feet 4 2 m eters 5 feet 1 5 meters 12 9 gpm 49 lpm 12 5 gpm 47 5 lpm 11 8 gpm 44 8 lpm 5 gpm 19 lpm 12 1 gpm 46 lpm 12 1 gpm 46...

Page 3: ...Wrench 7 16 Upper Standard Head Ring 1 2 Cylinder Mounting Nuts Not Shown 9 16 Cylinder Rod Locking Nut Step 2 Place Pump The pump must be installed so that the flapper valves will open and close The...

Page 4: ...you need once the plumbing is installed and liquid is being pumped 1 Open the air line 2 Set air line pressure to 90 psi 3 Using a very small flat head screwdriver start closing clockwise the right h...

Page 5: ...nder the force of gravity liquid will pass right through a diaphragm pump Also consider a diaphragm pump can not control a siphon condition They are used many times to start one lDISCHARGE FITTINGS PI...

Page 6: ...dry suction start performance of the pump and make clearing the valves easy Order Edson Clear Check V alves 69CL 150 1 5 lPUMPING AT THE PROPER SPEED When pumping liquid with solids the speed may be t...

Page 7: ...stallation is different so use the charts as a guideline 6 Example 1 The fill test at 30 GPM The diaphragm is going up and down at 56 cycles per minute The pump is approximately 6 ft above the liquid...

Page 8: ...6 to 7 psi and when the pump is stopped the pressure may hold or slowly returns to 0 4 If you do not get any pressure reading or if the gauge does not get to 4 psi and drops off to 0 as soon as the p...

Page 9: ...he cause is not obvious isolate the source Check air line for pressue and flow If ok discon nect the inlet and discharge plumbing from the pump and restart the pump If pump cycles without the plumbing...

Page 10: ...Edson Customer Service for details 4 Problem Pump base and or lines keep filling with solids Possible Causes a Line velocity is too slow to keep the solids in suspen sion b The percent of solids is t...

Page 11: ...S w Nut 5 16 24 Nut 160 B 376A Discharge Chamber 160 A 1207 Valve Assembly 160 A 1207 Valve Assembly 160 B 374B Head Ring 160 B 375A Suction Chamber 160 B 378A Pump Base 10 32 X 3 4 PHMS Parts 220ACA...