CO gas is lighter than air, it will moves higher in the room, install the dector due to the Figure 2. LPG
exists in lower side of the room, install the detector due to Figure 3. Install detector away from fans and
air absorbing equipments. CO detector, designed for detecting gas leakage and warning by sound and
red alarm led. Connecting alarm or security panels and fans by relay outputs. Detecting capability of
Ideal for home and office use due to the compact design.

Introduction

Figure:12

7/8

Power

Model

12V DC

220V AC

-

Power Comsumption

2.5W

External Horn Output

105g

Weight
Relay Output

1A 12V (COM, NC, NO)

Protection Area

50squaremeters

Sensor Type

Semi Conductor

Sensor Life

Avaible Conditions 5 Years

Heating

15 min.

DetectionTime

<2,5mins

Operating Temperature
Humidity

-10C +50C
0-95 Not Saturated

Siren Output

Piezoelectrical Buzzer

Led Display: Operating Green Led

Sound Level

85dB

Red Led

Housing

ABS

Color

White

Dimensions

143mm x 83mm x 30mm

Fuse

Auto

12V DC

Led Display: Alarm

1

2

3

4

9

7

8

7

9

3

2

1

4

5

7

9

8

5

Technical Specifications

Figure:1

Installation

Installation CD310 should be done with 2pcs of 6mm wall plugs and 2pcs of 3.5x30mm screw. Remove
upper part of plastic cover by the help of hutch(Figure 1, point 6). Install CD310 by using installation
holes and gas absorbing holes which refers to the base of the room, smooth plane of wall.
Install wall plugs and bottom part of plastic cover. Make suitable cable connection. Place uppert part of
plastic cover; gas absorbing holes refers to the base.
After power up, push test switch and test gas detector. Pushing test switch red led on and buzzer warns
by sound.

6

6

Figure:13

At A Glance To The Detector

6

9

9

CARBON MONOXIDE DETECTOR

CD310/330/330R

CARBON MONOXIDE DETECTOR

Yellow Led

Led Display: Fault

CD310

CD330R

CD330

10

Red Led- Alarm/Yellow Faulth

Test Switch

Green Led - Operating

Gas Absorbing Holes

Sound Emitting Hole

Hutch

Cable Holes

Label

Installation Holes

Power Supply Socket

Summary of Contents for CD 310

Page 1: ...AL CARBON MONOXIDE DETECTOR CD 310 CD 330 CD 330R EDS Elektronik Destek Sanayi ve Ticaret Ltd Þti Meclis Mah Teraziciler Cad Kýlýç Sok No 4 34785 S a r ý g a z i Ý s t a n b u l www eds com tr eds eds com tr 90 216 528 45 00 90 216 314 17 80 Ph Fax ...

Page 2: ...d Sound Level 85dB Red Led Housing ABS Color White Dimensions 143mm x 83mm x 30mm Fuse Auto 12V DC Led Display Alarm 1 2 3 4 9 7 8 7 9 3 2 1 4 5 7 9 8 5 Technical Specifications Figure 1 Installation Installation CD310 should be done with 2pcs of 6mm wall plugs and 2pcs of 3 5x30mm screw Remove upper part of plastic cover by the help of hutch Figure 1 point 6 Install CD310 by using installation ho...

Page 3: ...age to the heart and brain from oxygen starvation Carbon Monoxide originates from the combustion of any fossil fuel coal bottled and natural gas paraffin wood petrol diesel charcoal etc All Fossil fuel burning appliances produce CO this is normally vented through flues and chimneys to the outside atmosphere However if the process is not entirely efficient CO can build up to dangerous levels Exampl...

Page 4: ...ctions Panel Connections Power connection of the detector from a panelor a power supply by the double ribbed cable which has radius of 1 5square milimeters Sending alarm signal to the panel by the connection of double ribbed cable to the relay outputs For using relay outputs NC NO read instruction manual of panel According to the instruction manual of panel you may use suitable alarm Resisto B or ...

Reviews: