Edmonds ecopower EP900 Installation Instruction Download Page 2

INSTALLATION INSTRUCTION 

ecopower

®

 EP900 Hybrid Ventilator

Edmonds is a business division of CSR Building Products Limited ABN 55 008 631 356

 

10 Stanton Road, Seven Hills, NSW 2147 

Telephone 1300 858 674    

www.edmonds.com.au

Global

-

Mark

.

com

.

au®

Q

ua

lit

y M

ana

gement 

.

 ISO

 90

01

 

Step 4

Secure the two halves of the Varipitch by inserting self tapping screws or blind rivets into the 
Varipitch clips. Run a bead of silicone around the inside of the Varipitch seam. 

Note:

 DO NOT apply silicone to joint between flashing and Varipitch. This is a natural gutter to 

release any trapped condensation. 

Step 5

Fit the turbine to the Varipitch (Fig 4). Check that it is level and adjust by tilting if necessary. 
Fasten the turbine to the top of the Varipitch (for number of fasteners see Table 1).

wiring
THE ECOPOwER MUST bE wIRED by A qUALIfIED ELECTRICIAN.

 

Run a 

bead of 

silicone 

around 

Varipitch 

joint      

 (inside)

Ridge 

or apex

Fig 4

Brown

Active

Blue

Neutral

Green/Yellow

Earth

Table 1 -

 

Recommended Fastener Quantities

Unit Size 

(mm)

Head to 

Varipitch

Varipitch to 

Flashing

Flashing to Roof 

(Locate 6 close to 

Varipitch)

900

12

12

26

Either: 10 gauge 16mm tek screws with neo or 5/32 blind rivets are 

recommended. When non sealed rivets are used apply silicone over 

the rivets to seal.

Electrical Specification

EP900

Voltage

200-277 VAC 50/60 Hz

Current (A)

1.21

Power (W)

260

CONTROL DEVICES

The ecopower EP900 can be controlled by any digital means. Edmonds stocks a range of standard controllers for Temperature, 
Humidity and Internal Air Quality. The wiring connections for each are below.

240 VAC ROOM THERMOSTAT - EbERLE RTR-E 6705

Electrical Connections

3

Active 

Motor Connection

2

Not used for cooling

1

Active

240 VAC Mains Connection

N

Not used for cooling

N

Not used for cooling

ROOM HUMIDISTAT - SIEMENS qfA1001

Electrical Connections

1

Active 

240 VAC Mains Connection

2

Not used for dehumidification

3

Active

Motor Connection

INDOOR AIR qUALITy CONTROLLER - SIEMENS qPA84

Electrical Connections

Y1

Active 

Motor Connection

N

Neutral

Earth

Earth

240 VAC Mains Connection

N

Neutral

L

Active