Instruction manual
ES
PT
EN
FR
ref. 32508
13
activated, if it identifies another person, the running time is reset.
▶
Adjustable timer: the delay time could be set according to
customers’ requirements, the minimum time of this item is
10sec±3sec, and the maximum time is 5min±1min..
TEST
▶
Turn the TIME knob counterclockwise to the minimum. Turn the LUX
knob clockwise to the maximum (sun).
▶
Light; the lamp will not have the signal at the beginning. After 30
seconds of warm-up, the lamp starts to work. If the induction signal
is received, the lamp turns on. Although there is no other induction
signal, the lamp should stop working within 10 sec ± 3 seconds.
▶
Turn LUX counterclockwise to minimum (moon). If the ambient light
is more than 3 LUX, the lamp will not work. If the light is less than
3 LUX (dark), the sensor could work. Under no condition of induction
signal, the lamp should stop working within 10 sec ± 3 seconds.
Note
▶
When do day test, please turn the knob to LUX (SUN) position,
otherwise the lamp sensor will not work!
▶
It must be installed by an electrician or qualified personnel.
▶
Avoid installing it on uneven surfaces.
▶
There should be no obstacles and moving objects in front of the
sensor as it could affect the detection.
▶
Avoid installing it near areas of temperature alteration, air, such as
air conditioning, central heating, etc.
▶
Considering your safety, please do not open the cover after
installation..
PROBLEMS AND SOLUTIONS
IF IT DOES NOT WORK
▶
Por favor, compruebe si la conexión de cables de potencia y de
carga es correcta.
▶
Por favor, compruebe si la carga es buena.
▶
Por favor, compruebe si los juegos de luces corresponden a la luz
de la habitación.
SENSITIVITY IS POOR
▶
Please check whether there is any obstacle in front of the detection
sensor that may affect the signal.
▶
Please check if the ambient temperature is too high.
▶
Please check whether the induction signal source is in the detection
fields.
▶
Please check if the height corresponds to the height indicated in
the instructions.
▶
Please check if the sensor has the correct orientation.
THE SENSOR CANNOT AUTOMATICALLY SWITCH OFF
▶
Please check if there is continuous signal in the detection field.
▶
Please check if the time delay is the longest.
▶
Please check if the electrical current corresponds to that indicated
in the instructions.
Low sensitivity
High sensitivity