11
Technnical specifications CLS-5T
Power supply
110-240VAC, external switching power supply
12-24VDC as primary power or backup, 12V will reduce output
Loop output
Max current
10Arms
Max voltage
24Vpp
Frequency range
55Hz to 9870Hz @ 1Ω and 100μH
Distortion
<1% @ 1Ω DC and 80μH
Connection
Phoenix screw terminal
Inputs
Digital
Optical/coax
In 1
Phoenix connector/balanced input/PIN 8/10
8mV–1100mV 1�1Vrms (RMS)/5kΩ
In 2
RCA/phono, RCA - unbalanced input: 15mV-3500mV 3,5Vrms (RMS) /5kΩ
Indication
External door bell/telephone signal or trigger voltage can activate the
built-in alerting system with tone generator in the loop�
Metal loss correction/treble control
0 to +18dB correction of high frequency attenuation – internal control
Loop current
Loop current (6�)
Screwdriver adjusted
Indicators
Power connection
Yellow LED (1�)
Input
Green LED (2�)
Loop current
Blue LED (3�)
Size
WxHxD 210mm x 45mm x 130mm
Weight (net/gross)
1�06kg
1�22kg
Part No
212060
Product is designed to meet the system requirements of IEC60118-4, when correctly designed, installed,
commissioned and maintained� Specification data complied according to IEC62489-1� The installation guide is
based on information avaliable at the time of printing and is subject to change without notice�