Product maintenance and care

Under normal circumstances the product does not need any special maintenance. 
Should the unit become dirty, wipe it with a clean damp cloth. Do not use any solvents or 
detergents. 

Mounting and placement

CLS-5 can be wall-mounted (see template for wall mounting at the end of this Installation 
Guide) or placed on a flat and stable surface. The wires between the loop figuration and the 
driver should not exceed 10 meters and should be paired or twisted.

Important! The location must provide adequate unit ventilation .

The amplifier normally generates heat during operation and needs free space for plenty of 
ventilation on all sides. To prevent fire, overheating or discoloration of the nearby objects, 
the amplifier should not be placed close to fragile and easily flammable materials.

Installation setup

1.  Connect the loop wire to the amplifier’s loop connection terminal marked Loop (4.).
2.  Connect a suitable input signal source.
3.  Connect the amplifier to mains or a 12-24 VDC power source. Yellow LED (1.) 

illuminated.

Default settings

1.  Check that there is an input signal, green LED In (2.) illuminated.
2.  If microphone is connected to Mic input, adjust the microphone sensitivity (11.). 

Adjust the microphone sensitivity (8.) so the green LED In (2.) is illuminated during the 
program peaks.

3.  Adjust the magnetic field strength by turning the loop current potentiometer Loop 

(6.) until the program peaks reach 0dB, (400 mA/m). Verify the field strength with 
Univox

®

 FSM field strength meter enabling RMS measurement and 125 ms integration 

time. Check the sound quality with the loop receiver, Univox

®

 Listener. Some 

installations require adjustment of treble level. The treble control is located inside the 
CLS-5 (single control potentiometer inside the unit). When increasing the treble there 
is an increased risk of self-oscillation and distortion.

Summary of Contents for Univox CLS-5

Page 1: ...1 Univox CLS 5 Environment friendly loop amplifier for TV rooms and installations in elevators buses Installation Guide Univox CLS 5 art nr 212012...

Page 2: ...up 6 Default settings 6 Special settings for TV connection 7 Connecting an alert signal 7 Loop installation guidance 8 Technical description 9 Power 9 Loop Output 9 Inputs 9 Indication 9 Metal loss co...

Page 3: ...les to large TV lounges and meeting rooms Digital and coaxial inputs adjustment of time delay between the audio and video TV Sync and built in automatic SCART control are some of the features that ena...

Page 4: ...4 Product overview 1 6 5 10 9 Front panel Rear panel 3 4 Side 7 2 8 11 12 13 Terminal block...

Page 5: ...r for TV 10 SCART connector Ext for VHS DVD player etc 11 Microphone input 12 Digital input optical 13 Digital input coax User information CLS 5 should be installed and adjusted by a qualified technic...

Page 6: ...setup 1 Connect the loop wire to the amplifier s loop connection terminal marked Loop 4 2 Connect a suitable input signal source 3 Connect the amplifier to mains or a 12 24 VDC power source Yellow LED...

Page 7: ...ART output on the TV and the SCART input 9 on the CLS 5 Sound adjustment TV Sync 5 For adjustment of time delay between the audio and video signal use the TV sync adjustment potentiometer Connecting a...

Page 8: ...o or directly on metal constructions or reinforced structures Otherwise the field strength might be reduced substantially If the shortest side of the loop area is longer than 10 meters a figure eight...

Page 9: ...Coax Mic 3 5 mm 2 250 mV 5 k built in phantom power TV Ext SCART 35 mV 10 V 5k In 1 screw terminal 35 mV 10 V 5 k In 2 screw terminal 25 mV 10 V 5 k In 3 RCA phono 35 mV 330 Indication External door b...

Page 10: ...r maintenance Bo Edin AB shall not be held responsible or liable for interference to radio or TV equipment and or to any direct incidental or consequential damages or losses to any person or entity if...

Page 11: ...x FSM Basic Field Strength Meter Professional instrument for measurement of performance and certification of loop systems in accordance with IEC 60118 4 Univox Listener Induction loop receiver designe...

Page 12: ...systems created the very first true loop amplifier 1969 Ever since our mission is to serve the hearing community with the highest degree of service and performance with strong focus on Research and De...

Reviews: