Installation

1. Operating Environment

This switching hub must be installed and operated within the limits of 
specified operating temperature (32-131

0

F) and humidity (10-95% 

Noncondensing). Do not place objects on top of the unit. Do not obstruct any 
vents at the sides of the unit. Do not position the unit near any heating source 
such as heater, radiator, or direct exposure to sun. Prevent entering of water 
and moisture into the unit. If necessary, use dehumidifier to reduce humidity.

2. Connecting to network devices

The RJ-45 ports on the switch support Auto-MDI/MDI-X function which 
allows using straight-through or cross-over type cables to connect this switch 
to workstation or hub.

Connect one end of the network cable to the RJ-45 port on the rear panel, and 
connect the other end of the network cable to the RJ-45 port on the network 
device. Follow the same procedure to connect all the RJ-45 ports of the 
switch.  The UTP network cables must comply with EIA/TIA 568 
specifications and Category 5 standard for 1000Mbps data transmission.   
Maximum length, using UTP cable, between the switch and connected device 
is 100 meters (300ft).  Once the network cable is connected to both ends and 
the attached network device is powered on, the green LNK/ACT LED should 
be lit.

3. Connecting the power

Connect the output end of the power 
adapter to the power connector on the
rear panel of the unit.  Connect the
power adapter to the power outlet.
The green Power LED on the front 
panel should be lit.

Figure 2-1  Connect the power adapter

External Power Adapter