background image

56

 

RSTP pathcost [<portlist>] [<pathcost>|auto] 

 
Description: 
Set the RSTP pathcost on ports <portlist>. 
 
[<portlist>]: Port list (Default: All ports). 
[<pathcost>]: Number between 1 - 200000000. Auto means auto generated 
pathcost 
 

RSTP mcheck <portlist> 

 
Description: 
Force a recheck of the RSTP protocol on the ports in <portlist>. 
 
<portlist>: List of ports. 
 

RSTP Status 

 
Description: 
Show RSTP bridge instances and port states. 
 

RSTP Statistics 

 
Description: 
Show RSTP bridge instance and port statistics. 
 
 

All manuals and user guides at all-guides.com

Summary of Contents for ES-5160G+ V2

Page 1: ...ES 5160G v2 ES 5240G v2 16 24 Ports Gigabit Web Smart Switch with 4 ports mini GBIC User s Manual Version 1 0 August 2010 All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 2: ...owing two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation CE Mark Warning...

Page 3: ...on 9 Installing Network Cables 10 Functional Description 11 Jumbo Frame 11 Flow Control and Back Pressure 11 Mirror 11 VLAN 11 Trunk Aggregation 11 Quality of Service QoS 11 SNMP 11 Management guide 1...

Page 4: ...CP Status 34 RSTP Status 35 IGMP Status 36 Ping 37 Warm Restart 38 Factory Default 38 Software Upload 38 Product Specifications 39 Appendix Command Line Interface 40 Start up and Terminal configuratio...

Page 5: ...50 Aggregation Commands 52 LACP Commands 53 RSTP Commands 54 User Group Commands 57 QoS Commands 58 Mirror Commands 61 IP Commands 62 Dot1x Commands 64 IGMP Commands 66 Debug Commands 67 All manuals a...

Page 6: ...dth demanded files faster and get a real efficiency improvement with the user friendly Web based management interface This product also equips 4 mini GBIC slots for your flexible fiber connection Use...

Page 7: ...ack pressure Non blocking wire speed switching performance Provides 8K MAC address entries and 16 groups VLAN table Supports firmware upgrade SNMP Supports Jumbo frame 9600 bytes Supports 500K bytes b...

Page 8: ...d link is established and there is data transmitting receiving 10 100M Off No valid link on this port or the port is connected at 1000 Mbps Port Operation The auto negotiation feature allows those por...

Page 9: ...the electric service standards around the world the switch is designed to afford the power supply in the range from 100 to 240 VAC 50 60 Hz Please make sure that your outlet standard to be within thi...

Page 10: ...2 Plug the switch with the female end of the provided power cord and plug the male end to the power outlet Rack mount Installation The switch may be standalone or mounted in a rack Rack mounting faci...

Page 11: ...and obtain the optimal performance An appropriate cable that corresponds to different transmitting receiving speed is required To choose a suitable cable please refer to the following table Media Spe...

Page 12: ...ble to monitor the traffic of the specified port VLAN With VLAN supported the network can be segmented in groups to reduce the collisions from widely broadcasting The device supports both port based V...

Page 13: ...started as the following configuration 1 Data rate 115200 baud 2 Data format 8 data bits 1 stop bit and no parity 3 Flow control none 4 Click the property icon select settings make sure that The Func...

Page 14: ...t value to pass the authentication Also you can initialize the Password in the configuration of System 3 After authentication procedure the following page shows up and then you may click the hyperlink...

Page 15: ...14 System The System window provides the switch information and allows users to configure the switch properties All manuals and user guides at all guides com...

Page 16: ...rface Name Defines the user defined device name Password The Login password the Default value is blank or random value Inactivity Timeout secs The time of automatic broken network SNMP enabled Select...

Page 17: ...16 Port This Port Configuration page shows the link status of each port and allows users to configure speed flow control for each port All manuals and user guides at all guides com...

Page 18: ...o disable Drop frames after excessive collisions Enable or disable drop of frames when excessive collisions occur in half duplex mode To save the configuration of the system click Apply to save You ca...

Page 19: ...ck Delete Refresh to clear refresh this VLAN group Note 1 When a port is configured to a specific VLAN group a PVID that corresponding to the VLAN id will be assigned automatically to this port Ex whe...

Page 20: ...e for the port VLAN aware ports will strip the VLAN tag from received frames and insert the tag in transmitted frames except PVID VLAN unaware ports will not strip the tag from received frames or inse...

Page 21: ...groups and the aggregation mode To set up the Port trunk groups put the ports number into the same Aggregation group There are eight groups to choose Don t forget to click Apply to save the setting Al...

Page 22: ...LACP as long as they are not already configured as part of a static trunk If ports on another device are also configured as LACP the switch and the other device will negotiate a trunk link between th...

Page 23: ...l messages and dynamically adjusting the type of protocol messages the RSTP node transmits If RSTP is using 802 1D BPDUs on a port and receives an RSTP BPDU after the migration delay expires RSTP rest...

Page 24: ...e configuration messages at regular intervals Forward Delay The maximum time in seconds the root device will wait before changing states i e discarding to learning to forwarding This delay is required...

Page 25: ...ials for authentication When 802 1X is enabled you need to configure the parameters for the authentication process that runs between the client and the switch i e authenticator as well as the client i...

Page 26: ...nts either dot1x aware or otherwise This is the default setting Force Unauthorized Forces the port to deny access to all clients either dot1x aware or otherwise Port State Display the current status o...

Page 27: ...Reauthentication to be enabled or disabled on the port Reauthentication Period Set the time period after which a connected client must be re authenticated EAP timeout Set the time that an interface o...

Page 28: ...c Router Ports Set or show IGMP administrative router ports Unregistered IPMC Flooding enabled Set or show forwarding mode for unregistered not joined IP multicast traffic Will flood when enabled and...

Page 29: ...p In IEEE 802 1p priority mode when a switch port receives an untagged frame a frame without priority tag the port s default priority tag will be inserted into the frame before any other process This...

Page 30: ...shown below The DSCP mode QoS gives packet priority by the types of the incoming packets DSCP value s range is between 0 and 63 Give the priorities as normal high low for each precedence types then c...

Page 31: ...traffic of the monitored ports Mirror Configuration 1 Select those ports that are going to be monitored by marking the checkboxes in Monitor Source column 2 Click the drop list in Mirror Port column S...

Page 32: ...affic into or out of the switch Traffic that falls within the rate limit is transmitted while packets that exceed the acceptable amount of traffic are dropped This page allows users to limit the bandw...

Page 33: ...k 2k 4k 8k 16k 32k 64k or No limit To perform storm control 1 Click on each drop list to specify a speed for each frame type 2 Click the Apply button to execute your configuration Statistics Overview...

Page 34: ...see the detailed transmitting and receiving status of each port Please click the hyperlinks above to select a port You may also click the Clear button to clean all statistics or click the Refresh butt...

Page 35: ...ACP Status LACP Status is provided for users to see the detailed LACP Aggregation status of each port You may also click the Refresh button to renew the info All manuals and user guides at all guides...

Page 36: ...sisting of the bridge priority and MAC address where the address is taken from the switch system Hello time Set or show the RSTP System Hello time Number between 1 10 default is 2 Maxage Set or show t...

Page 37: ...atus is provided for users to see the detailed status of each port You may also click the Refresh button to renew the info IGMP Querier Set or Show IGMP querier state per VLAN All manuals and user gui...

Page 38: ...ectedness Target IP Address Indicates the IP Address of the test destination Count Number of echo requests to send default 1 Timeout Timeout in seconds to wait for each reply default 2 In the below ta...

Page 39: ...store the factory default value click the Yes button Note The IP address of the device will also be configured as factory default setting which is 192 168 2 1 Software Upload This Software Upload page...

Page 40: ...100 BASE TX Category 5 UTP STP RJ 45 1000 BASE T Category 5e 6 or enhanced UTP STP Fiber depend on mini GBIC types Network Data Rate 10 100 1000 Mbps Auto negotiation Transmission Mode 10 100 Mbps Fu...

Page 41: ...at 8 data bits 1 stop bit and no parity 3 Flow control none 4 Click the property icon select settings make sure that The Function arrow and ctrl keys act as Terminal keys Emulation VT 100 Login Logout...

Page 42: ...axes will be shown If given after a command the syntax and a description of the command will be shown Entering Commands To give any command please key in your command and press enter EX 1 Type System...

Page 43: ...ommands VLAN VLAN commands Aggr Aggregation commands LACP IEEE 802 3ad Link Aggregation commands RSTP IEEE 802 1w Rapid Spanning Tree commands User Group User Group commands QoS QoS commands Mirror Mi...

Page 44: ...pIP Preserve IP configuration default Not preserved System Name name Description Set or show the system name name String of up to 16 characters default Show system name System Reboot Description Reboo...

Page 45: ...ing default Show current value Trapcommunity community string Description Set or show SNMP trap community string community string New community string default Show current value Sytem Power Saving ful...

Page 46: ...nsole password The empty string disables the password check password Password string of up to 16 characters Console Timeout timeout Description Set or show the console inactivity timeout in seconds Th...

Page 47: ...e for the port portlist Port list Default All ports Port Mode portlist mode Description Set or show the speed and duplex mode for the port portlist Port list Default All ports mode Port speed and dupl...

Page 48: ...ption to return to default setting portlist Port list default All ports framesize reset Maximum frame size 1518 9600 or reset to 1518 bytes default Show maximum frame size Port Statistics portlist cle...

Page 49: ...hex string optionally separated with dashes or colons e g 010203ABCDEF or 01 02 03 AB CD EF or 01 02 03 AB CD EF portlist Port list Use none to specify no ports vid VLAN ID 1 4094 default 1 MAC Delet...

Page 50: ...e MAC address table for VLAN ID list vidlist VLAN ID list MAC Flush Description Removes non locked entries from the switch MAC table MAC Agetime agetime Description Set or show the MAC age timer in se...

Page 51: ...mode port VLAN ID and accepted frame type for the port and the permanently stored VLAN table portlist Port list default All ports VLAN Add vidlist portlist Description Add VLAN entry and include port...

Page 52: ...d on the port will be classified to this VLAN ID Frames classified to this VLAN ID will be sent untagged on the port portlist Port list default All ports vid none Port VLAN ID 1 4094 default Show PVID...

Page 53: ...st Aggregation port list Aggr Delete portlist Description Delete link aggregation group portlist Port list Aggregations including any of the ports will be deleted Aggr Lookup portlist Description Look...

Page 54: ...able disable Description Enable or disable the LACP protocol on ports portlist portlist Port list Default All ports enable disable Enable or disable LACP Key portlist key auto Description Set the LACP...

Page 55: ...atus RSTP Statistics RSTP Configuration portlist Description Show RSTP configuration portlist Port list Default All ports RSTP sysprio sysprio Description Set or show the RSTP System Priority sysprio...

Page 56: ...ible with old STP RSTP Mode portlist enable disable Description Enable or disable the RSTP protocol on ports portlist portlist Port list Default All ports enable disable Enable or disable RSTP aggr en...

Page 57: ...1 200000000 Auto means auto generated pathcost RSTP mcheck portlist Description Force a recheck of the RSTP protocol on the ports in portlist portlist List of ports RSTP Status Description Show RSTP...

Page 58: ...r groups User Group Add grouplist portlist Description Add user group entry including the ports grouplist User group ID list portlist Port list default All ports User Group Delete grouplist Descriptio...

Page 59: ...ping default class default VLAN user priority and DSCP mapping for the port portlist Port list default All ports QoS Mode portlist tag port diffserv Description Set or show the QoS mode for the port p...

Page 60: ...LAN user priority for received untagged frames portlist Port list default All ports tagprio VLAN tag user priority 0 7 default Show user priority QoS Shaper portlist enable disable rate Description Se...

Page 61: ...m Control traffic type enable disable rate Description Set or show the storm control configuration The allowed frame rates for ICMP frames learn frames multicasts broadcasts and flooded unicasts are c...

Page 62: ...ource ports Mirror Port port Description Set or show the mirror destination port port Mirror destination port default Show mirror port Mirror Source portlist enable disable Description Set or show the...

Page 63: ...up or show IP configuration ipaddress IP address default Show IP configuration ipmask IP subnet mask default Subnet mask for address class ipgateway Default IP gateway default 0 0 0 0 vid VLAN ID 1 40...

Page 64: ...ion Show the content of the ARP table IP DHCP enable disable Description Activate or deactivate the DHCP protocol enable disable Enable disable DHCP default Show DHCP mode All manuals and user guides...

Page 65: ...1x Mode enable disable Description Enable or disable 802 1X process for the switch enable disable new mode default Show current configuration Dot1x State portlist Auto ForceAuthorized ForceUnauthorize...

Page 66: ...Dot1x Statistics portlist Description Show 802 1X statistics for the port portlist Port list default All ports Dot1x Reauthenticate portlist now Description Refresh restart 802 1X authentication proce...

Page 67: ...how the IGMP configuration IGMP Status Description Show the IGMP operational status and statistics IGMP Groups vidlist Description Show IGMP groups for given VLANs IGMP Mode enable disable Description...

Page 68: ...st traffic Will flood when enabled and forward to router ports only when disabled default Show current mode Debug Commands Commands at Debug level Debug Read Register block subblock address Debug Read...

Reviews: