background image

 

 

 

 

 

 

 

 

 

 

 

ES-5160G+ v2 / ES-5240G+ v2 

16 / 24 Ports Gigabit Web Smart Switch with 4 ports mini-GBIC   

 

User’s Manual 

Version 1.0 / August, 2010 

Summary of Contents for ES-5160G V2

Page 1: ...ES 5160G v2 ES 5240G v2 16 24 Ports Gigabit Web Smart Switch with 4 ports mini GBIC User s Manual Version 1 0 August 2010...

Page 2: ...is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired ope...

Page 3: ...9 Rack mount Installation 9 Installing Network Cables 10 Functional Description 11 Jumbo Frame 11 Flow Control and Back Pressure 11 Mirror 11 VLAN 11 Trunk Aggregation 11 Quality of Service QoS 11 SNM...

Page 4: ...tailed Statistics 33 LACP Status 34 RSTP Status 35 IGMP Status 36 Ping 37 Warm Restart 38 Factory Default 38 Software Upload 38 Product Specifications 39 Appendix Command Line Interface 40 Start up an...

Page 5: ...mands 48 VLAN Commands 50 Aggregation Commands 52 LACP Commands 53 RSTP Commands 54 User Group Commands 57 QoS Commands 58 Mirror Commands 61 IP Commands 62 Dot1x Commands 64 IGMP Commands 66 Debug Co...

Page 6: ...re now able to transfer high bandwidth demanded files faster and get a real efficiency improvement with the user friendly Web based management interface This product also equips 4 mini GBIC slots for...

Page 7: ...ntrol and half duplex back pressure Non blocking wire speed switching performance Provides 8K MAC address entries and 16 groups VLAN table Supports firmware upgrade SNMP Supports Jumbo frame 9600 byte...

Page 8: ...g Blinking Green A valid link is established and there is data transmitting receiving 10 100M Off No valid link on this port or the port is connected at 1000 Mbps Port Operation The auto negotiation f...

Page 9: ...e To be compatible with the electric service standards around the world the switch is designed to afford the power supply in the range from 100 to 240 VAC 50 60 Hz Please make sure that your outlet st...

Page 10: ...the relevant components 2 Plug the switch with the female end of the provided power cord and plug the male end to the power outlet Rack mount Installation The switch may be standalone or mounted in a...

Page 11: ...TP cable To make a valid connection and obtain the optimal performance An appropriate cable that corresponds to different transmitting receiving speed is required To choose a suitable cable please ref...

Page 12: ...packets and hence is able to monitor the traffic of the specified port VLAN With VLAN supported the network can be segmented in groups to reduce the collisions from widely broadcasting The device sup...

Page 13: ...tion software should be started as the following configuration 1 Data rate 115200 baud 2 Data format 8 data bits 1 stop bit and no parity 3 Flow control none 4 Click the property icon select settings...

Page 14: ...he password 1234 default value to pass the authentication Also you can initialize the Password in the configuration of System 3 After authentication procedure the following page shows up and then you...

Page 15: ...14 System The System window provides the switch information and allows users to configure the switch properties...

Page 16: ...ccess the WEB based management interface Name Defines the user defined device name Password The Login password the Default value is blank or random value Inactivity Timeout secs The time of automatic...

Page 17: ...16 Port This Port Configuration page shows the link status of each port and allows users to configure speed flow control for each port...

Page 18: ...low control or unmark to disable Drop frames after excessive collisions Enable or disable drop of frames when excessive collisions occur in half duplex mode To save the configuration of the system cli...

Page 19: ...iguration List then click Delete Refresh to clear refresh this VLAN group Note 1 When a port is configured to a specific VLAN group a PVID that corresponding to the VLAN id will be assigned automatica...

Page 20: ...the VLAN awareness mode for the port VLAN aware ports will strip the VLAN tag from received frames and insert the tag in transmitted frames except PVID VLAN unaware ports will not strip the tag from...

Page 21: ...on This page shows the aggregation groups and the aggregation mode To set up the Port trunk groups put the ports number into the same Aggregation group There are eight groups to choose Don t forget to...

Page 22: ...ports on the switch as LACP as long as they are not already configured as part of a static trunk If ports on another device are also configured as LACP the switch and the other device will negotiate...

Page 23: ...ng the incoming protocol messages and dynamically adjusting the type of protocol messages the RSTP node transmits If RSTP is using 802 1D BPDUs on a port and receives an RSTP BPDU after the migration...

Page 24: ...ted ports should receive configuration messages at regular intervals Forward Delay The maximum time in seconds the root device will wait before changing states i e discarding to learning to forwarding...

Page 25: ...to first submit credentials for authentication When 802 1X is enabled you need to configure the parameters for the authentication process that runs between the client and the switch i e authenticator...

Page 26: ...he port to grant access to all clients either dot1x aware or otherwise This is the default setting Force Unauthorized Forces the port to deny access to all clients either dot1x aware or otherwise Port...

Page 27: ...hentication Enabled Set Reauthentication to be enabled or disabled on the port Reauthentication Period Set the time period after which a connected client must be re authenticated EAP timeout Set the t...

Page 28: ...eceive multicast traffic Router Ports Set or show IGMP administrative router ports Unregistered IPMC Flooding enabled Set or show forwarding mode for unregistered not joined IP multicast traffic Will...

Page 29: ...ct the QoS Mode 1 802 1p In IEEE 802 1p priority mode when a switch port receives an untagged frame a frame without priority tag the port s default priority tag will be inserted into the frame before...

Page 30: ...P mode is configured as shown below The DSCP mode QoS gives packet priority by the types of the incoming packets DSCP value s range is between 0 and 63 Give the priorities as normal high low for each...

Page 31: ...trators to analyze and monitor the traffic of the monitored ports Mirror Configuration 1 Select those ports that are going to be monitored by marking the checkboxes in Monitor Source column 2 Click th...

Page 32: ...f a network to limit traffic into or out of the switch Traffic that falls within the rate limit is transmitted while packets that exceed the acceptable amount of traffic are dropped This page allows u...

Page 33: ...te Allowed values are 1k 2k 4k 8k 16k 32k 64k or No limit To perform storm control 1 Click on each drop list to specify a speed for each frame type 2 Click the Apply button to execute your configurati...

Page 34: ...provided for users to see the detailed transmitting and receiving status of each port Please click the hyperlinks above to select a port You may also click the Clear button to clean all statistics or...

Page 35: ...34 LACP Status LACP Status is provided for users to see the detailed LACP Aggregation status of each port You may also click the Refresh button to renew the info...

Page 36: ...ique identifier for this bridge consisting of the bridge priority and MAC address where the address is taken from the switch system Hello time Set or show the RSTP System Hello time Number between 1 1...

Page 37: ...36 IGMP Status IGMP Status is provided for users to see the detailed status of each port You may also click the Refresh button to renew the info IGMP Querier Set or Show IGMP querier state per VLAN...

Page 38: ...Apply to ping the connectedness Target IP Address Indicates the IP Address of the test destination Count Number of echo requests to send default 1 Timeout Timeout in seconds to wait for each reply de...

Page 39: ...e Factory Default To restore the factory default value click the Yes button Note The IP address of the device will also be configured as factory default setting which is 192 168 2 1 Software Upload Th...

Page 40: ...ory 3 4 5 UTP STP RJ 45 100 BASE TX Category 5 UTP STP RJ 45 1000 BASE T Category 5e 6 or enhanced UTP STP Fiber depend on mini GBIC types Network Data Rate 10 100 1000 Mbps Auto negotiation Transmiss...

Page 41: ...1 Data rate 115200 baud 2 Data format 8 data bits 1 stop bit and no parity 3 Flow control none 4 Click the property icon select settings make sure that The Function arrow and ctrl keys act as Terminal...

Page 42: ...ist of the command syntaxes will be shown If given after a command the syntax and a description of the command will be shown Entering Commands To give any command please key in your command and press...

Page 43: ...Port commands MAC MAC commands VLAN VLAN commands Aggr Aggregation commands LACP IEEE 802 3ad Link Aggregation commands RSTP IEEE 802 1w Rapid Spanning Tree commands User Group User Group commands QoS...

Page 44: ...fault configuration keepIP Preserve IP configuration default Not preserved System Name name Description Set or show the system name name String of up to 16 characters default Show system name System R...

Page 45: ...tring New community string default Show current value Trapcommunity community string Description Set or show SNMP trap community string community string New community string default Show current value...

Page 46: ...word Description Set or show the console password The empty string disables the password check password Password string of up to 16 characters Console Timeout timeout Description Set or show the conso...

Page 47: ...w control mode and state for the port portlist Port list Default All ports Port Mode portlist mode Description Set or show the speed and duplex mode for the port portlist Port list Default All ports m...

Page 48: ...me size Use the reset option to return to default setting portlist Port list default All ports framesize reset Maximum frame size 1518 9600 or reset to 1518 bytes default Show maximum frame size Port...

Page 49: ...ss MAC address 12 digit hex string optionally separated with dashes or colons e g 010203ABCDEF or 01 02 03 AB CD EF or 01 02 03 AB CD EF portlist Port list Use none to specify no ports vid VLAN ID 1 4...

Page 50: ...ist Description Show the MAC address table for VLAN ID list vidlist VLAN ID list MAC Flush Description Removes non locked entries from the switch MAC table MAC Agetime agetime Description Set or show...

Page 51: ...ist Description Show the VLAN aware mode port VLAN ID and accepted frame type for the port and the permanently stored VLAN table portlist Port list default All ports VLAN Add vidlist portlist Descript...

Page 52: ...Untagged frames received on the port will be classified to this VLAN ID Frames classified to this VLAN ID will be sent untagged on the port portlist Port list default All ports vid none Port VLAN ID 1...

Page 53: ...including ports portlist Aggregation port list Aggr Delete portlist Description Delete link aggregation group portlist Port list Aggregations including any of the ports will be deleted Aggr Lookup po...

Page 54: ...s LACP Mode portlist enable disable Description Enable or disable the LACP protocol on ports portlist portlist Port list Default All ports enable disable Enable or disable LACP Key portlist key auto D...

Page 55: ...mcheck portlist RSTP Status RSTP Statistics RSTP Configuration portlist Description Show RSTP configuration portlist Port list Default All ports RSTP sysprio sysprio Description Set or show the RSTP S...

Page 56: ...rsion normal use RSTP compat compatible with old STP RSTP Mode portlist enable disable Description Enable or disable the RSTP protocol on ports portlist portlist Port list Default All ports enable dis...

Page 57: ...pathcost Number between 1 200000000 Auto means auto generated pathcost RSTP mcheck portlist Description Force a recheck of the RSTP protocol on the ports in portlist portlist List of ports RSTP Status...

Page 58: ...escription Show the user groups User Group Add grouplist portlist Description Add user group entry including the ports grouplist User group ID list portlist Port list default All ports User Group Dele...

Page 59: ...VLAN user priority mapping default class default VLAN user priority and DSCP mapping for the port portlist Port list default All ports QoS Mode portlist tag port diffserv Description Set or show the...

Page 60: ...t or show the default VLAN user priority for received untagged frames portlist Port list default All ports tagprio VLAN tag user priority 0 7 default Show user priority QoS Shaper portlist enable disa...

Page 61: ...policer rate 0k is disable QoS Storm Control traffic type enable disable rate Description Set or show the storm control configuration The allowed frame rates for ICMP frames learn frames multicasts br...

Page 62: ...t and mirror mode for source ports Mirror Port port Description Set or show the mirror destination port port Mirror destination port default Show mirror port Mirror Source portlist enable disable Desc...

Page 63: ...way vid Description Setup or show IP configuration ipaddress IP address default Show IP configuration ipmask IP subnet mask default Subnet mask for address class ipgateway Default IP gateway default 0...

Page 64: ...63 IP Arp Description Show the content of the ARP table IP DHCP enable disable Description Activate or deactivate the DHCP protocol enable disable Enable disable DHCP default Show DHCP mode...

Page 65: ...02 1X configuration Dot1x Mode enable disable Description Enable or disable 802 1X process for the switch enable disable new mode default Show current configuration Dot1x State portlist Auto ForceAuth...

Page 66: ...default Show current configuration Dot1x Statistics portlist Description Show 802 1X statistics for the port portlist Port list default All ports Dot1x Reauthenticate portlist now Description Refresh...

Page 67: ...iguration Description Show the IGMP configuration IGMP Status Description Show the IGMP operational status and statistics IGMP Groups vidlist Description Show IGMP groups for given VLANs IGMP Mode ena...

Page 68: ...d not joined IP multicast traffic Will flood when enabled and forward to router ports only when disabled default Show current mode Debug Commands Commands at Debug level Debug Read Register block subb...