EdilKamin WIDRO 85 Instructions For Installation, Use And Maintenance Manual Download Page 11

11

ENGLISH

INSTALLATION

DELIVERY

The packaging can provide a useful indication of the product’s condition. Check the packaging on receipt and report 
any anomalies to the reseller straight away.

The packaging consists of a single pack with the contents as below.

Description

Number in 
the figure 
below

Quantity

(pcs)

Use

Fireplace

1

*

Side and rear refractory 
elements 

5

Handle for 
lifting the door
with screws

 (1)

1

can be used either as a fixed handle (by fastening it with 
the screws) or as a detachable handle, using the relevant 
bushes.

INSTALLER

1

Summary of Contents for WIDRO 85

Page 1: ...WIDRO 85 WIDRO 85 CS WOOD BURNING THERMO FIREPLACE For all updates visit www edilkamin com EN Installation use and maintenance page 2...

Page 2: ...ACE trade name EDILKAMIN models WIDRO 85 and WIDRO 85 CS SERIAL NO Rating plate reference WIDRO 85 and WIDRO 85 CS Declaration of perfor mance DoP EK no 203 The liability of the manufacturer is limite...

Page 3: ...located above the glass under the casing and can also be accessed once the product has been installed kW kg h B R L bar Max fuel consumption Max Verbrauch von Brennmaterial Consommation max de combus...

Page 4: ...r and smoke in the room Cleaning the fumes duct with various substances DO NOT ATTEMPT HOME GROWN CLEANING SOLUTIONS USING INFLAMMABLE PRODUCTS Risk of fire and blowback Cleaning the glass pane while...

Page 5: ...take into consideration local regulations The thermal discharge valve must be connected to the cooling circuit with a pressure of at least 1 5 bar AL coil supply always pressurised minimum 1 5 bar VS...

Page 6: ...does not match the chimney system diameter which must be sized accordingly TECHNICAL CHARACTERISTICS in accordance with EN 13229 The data shown below refers to the actual installation and use and was...

Page 7: ...7 ENGLISH DIMENSIONS WIDRO 85 dimensions in cm USER INSTALLER 102 103 99 20 13 85 51 72 5 71 139 74 71 69 5 maximum extension of feet 8 cm 164 172 82 31 52 55 delivery 1 delivery 1 return 1...

Page 8: ...DIMENSIONS WIDRO 85 CS dimensions in cm USER INSTALLER 102 1 2 connectors for coil maximum extension of feet 8 cm 85 51 103 99 20 72 5 71 69 5 13 int 71 139 164 172 74 82 31 52 55 delivery 1 delivery...

Page 9: ...y fashion Always move the stove vertically with suitable equipment and in compliance with safety regulations Do not turn the package over and handle all parts requiring installation with care TO REMOV...

Page 10: ...GET DAMAGED USE THE FEET MAY GET DAMAGED USE THE WHEELS after screwing the feet on THE WHEELS after screwing the feet on PICK UP POINTS FOR HANDLING The monobloc is equipped with four hooks to facilit...

Page 11: ...eseller straight away The packaging consists of a single pack with the contents as below Description Number in the figure below Quantity pcs Use Fireplace 1 Side and rear refractory elements 5 Handle...

Page 12: ...STALLATION LOOSEN THE SCREWS ONLY AFTER THE PRODUCT HAS BEEN POSITIONED DO NOT SHIFT THE PRODUCT WITHOUT THE LOCKING SCREWS LOOSEN THE LOCKING SCREWS ON THE SIDES IN ORDER TO LIFT THE DOOR locking scr...

Page 13: ...mbly sequence for REFRACTORY ELEMENTS 1 2 Position the LH SIDE element 3 Position the REAR element 4 5 Position the RH SIDE element 6 Position A REFRACTORY ELEMENTS on top ONLY LIGHT THE PRODUCT WITH...

Page 14: ...losing one or more plates P must be applied to the inner frame for the door To access the inner frame of the door remove the cover door located on the fireplace casing on both sides without plates sta...

Page 15: ...ility of the installation space The room must have a volume of at least 70 m3 The appliance may not be installed in a bedroom bathroom or in the same room as other equipment which draws air for combus...

Page 16: ...ainst overheating The insulation to be used will depend on the type of surface in question Check on the chimney system s data plate the safety distances to be kept in the presence of combustible mater...

Page 17: ...e flue inlet and the flue itself must among other regulatory requirements receive the smoke from a single product the outlets of multiple appliances may not be conveyed into a single flue have a mainl...

Page 18: ...metres in vertical length must be waterproof and thermally insulated to ensure proper draught preferably provide a collection chamber for unburnt fuel and condensates must be at least in the T400 cat...

Page 19: ...ce s air intake with a pipe that may also be flexible Increase the diameter of the pipe if the pipe is not smooth assess any load loss A maximum length of 5 metres is recommended with no more than 3 b...

Page 20: ...t part Remove pre cut part P P from the left hand side from the left hand side Unscrew the plate Unscrew the plate P1 P1 on the right hand side to be on the right hand side to be reused to close the h...

Page 21: ...ed according to the panel manufacturer s instructions The material used in the circuit must be suitable to withstand overheating Direct plumbing to radiators prevents proper operation owing to the sma...

Page 22: ...t directly with mains supply pressure since this may be in excess of the appliance s pressure rating and result in damage to the appliance itself The safety line to the expansion vessel must be able t...

Page 23: ...The appliance must be correctly sized installed The appliance must be correctly sized installed maintained and operated in compliance with local and maintained and operated in compliance with local a...

Page 24: ...24 ENGLISH HYDRAULIC INSTALLATION VENT manual COMPARTMENT FOR THERMAL DISCHARGE VALVE PROBE for CS version THERMAL DISCHARGE VALVE PROBE for CS version INSTALLER...

Page 25: ...cally in relation to the standard position by proceeding as follows proceeding as follows remove the copper connectors remove the copper connectors T2 T2 to be used on to be used on the other side the...

Page 26: ...s pre assembled hydraulic kits for open vessel and closed vessel installation Ask your local distributor for details Hydraulic parts are also available control unit valves etc Position the control uni...

Page 27: ...up The gather hood can be made with fireproof panels plasterboard can be made with fireproof panels plasterboard or gypsum slabs during construction the hot air or gypsum slabs during construction the...

Page 28: ...28 ENGLISH INSTALLATION FOR INSTALLER Possible adjustment of smoothness loosening or tightening of sliding action of the door using the Allen screws INSTALLER...

Page 29: ...is sold in a single package TEMPLATE FOR GATHER HOOD TEMPLATE FOR GATHER HOOD Optional to position before finishing cladding and frame for its placement SPIT UNIT WITH STAINLESS STEEL SPIT UNIT WITH...

Page 30: ...e door OPENING THE DOOR WITH VERTICAL MOVEMENT LOCK LEVER OPENING THE DOOR WITH VERTICAL MOVEMENT LOCK LEVER LR at the TOP at the TOP Use the handle detachable which is fixed with screws Use the handl...

Page 31: ...the indications and Description Effect Position 1 Ignition maximum power Primary air sent entirely to the combustion chamber plus turbo air all to the RH Primary air sent entirely to the combustion c...

Page 32: ...e to increase draught with the draught lever 1 To open unlock lever A by moving it to the right R pull it forward and lock it to the left L 2 To close unlock lever A by moving it to the right R push i...

Page 33: ...h elm or other class A1 woods in accordance with UNI EN ISO 17225 5 Avoid the prolonged use of woods rich in aromatic oils e g eucalyptus This may deteriorate the cast iron components Use the recommen...

Page 34: ...few times at rated capacity Ignition with the combustion chamber Ignition with the combustion chamber cold cold 1 Check that the existing ash bed is not too high If the 1 Check that the existing ash...

Page 35: ...nnot constitute grounds for complaints that cannot constitute grounds for complaints ODOURS On first ignition there may be a slight smell of paint which will disappear in a short time REFRACTORY ELEME...

Page 36: ...h grille G G and pull out the tray and pull out the tray V V Only place the ash removed in non combustible Only place the ash removed in non combustible containers bear in mind that the residual ember...

Page 37: ...eration to protect people and property Open the fireplace door with vertical opening Remove the deflector A Brush S Close the door Unscrew plate B from both sides Clean and vacuum C Once the dirt has...

Page 38: ...osed In particularly humid areas it may be necessary to disconnect the air intake and fume connector SPARE PARTS For any spare parts contact your dealer or technician The names of Edilkamin technical...

Page 39: ...s of operation it is normal for a slight layer of soot to form on the glass 4 If a fire starts in the flue or you need to immediately stop combustion in the fireplace if you can do so safely remove th...

Page 40: ...code 942139 GB 07 21 B w w w e d i l k a m i n c o m 942139 GB The names of Edilkamin official authorised technical assistance centres TAC and distributors are available ONLY at www edilkamin com...

Reviews: