8
ENGLISH
TECHNICAL DATA
USER/INSTALLER
Manufacturer
Edilkamin S.p.A.
Trademak
Edilkamin
Model Identifier
Pellkamin 8 Evo
Description
Mechanically space heater fired by wood pellets
Indirect heating functionality
no
Direct heat output (space heat output)
8,3 kW
CPR harmonised standard
EN 14785
Notified Body
Acteco srl (Via Amman 41 ,33084 Cordenons-PN-Italy) NB1880
Fuel
Preferred fuel
(unique)
PM
OGC
CO
NOx
PM
OGC
CO
NOx
Compressed wood with moisture content < 12 %
yes
16
3
91
104
18
3
244
74
Observe the specific precautions for installation, assembly and maintenance indicated in the manual accompanying the product
Up to 1/1/2022
From 01/01/2022
ɻ
s
[%]
85,8
ɻ
s
[%]
85,8
EEI [%]
126
EEI [%]
126
Energy Efficiency Class
A+
A+
Calculations according to the council commission regulation (EU) 2015/1186 and 2015/1185
BLF =1,45
F5 not of relevance
Heat output
Useful efficiency (NCV as received)
Item
Symbol
Value
Unit
Item
Symbol
Value
Unit
Nominal heat output
P
nom
8,3
kW
ɻ
th,nom
89,9
%
Minimum heat output
(indicative)
P
min
3,5
kW
ɻ
th,min
93,9
%
Auxiliary electricity consumption
Item
Symbol
Value
Unit
NO
At nominal heat output
el
max
0,140
kW
NO
At minimum heat
output
el
min
0,048
kW
NO
In standby mode
el
sb
0,002
kW
NO
NO
F(4)
2,1
%
CC =2,5
yes
F (2)
7,0
%
up to 2022
F (2)
7,0
%
from 2022
NO
NO
with distance control option
yes
F (3)
1,0
%
up to 2022
F (3)
1,0
%
from 2022
Contact details
Name and address of the manufacturer
www.edilkamin.com
EDILKAMIN S.p.A.
Via Mascagni 7
Legal Representative
20045 Lainate (MI) – ITALY
Paolo Gusella
TECHNICAL DOCUMENTATION FOR LOCAL SPACE HEATERS ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 AND 2015/1186
Type of heat output/room temperature control (select one)
Space heating emissions at nominal heat output
Space heating emissions at minimum heat
output
Only required if correction factors F(2) or F(3) are applied.
(*) PM = particulate matter, OGCs = organic gaseous compounds, CO = carbon monoxide, NOx = nitrogen oxides
mg/m3 at 13%O2
mg/m3 at 13%O2
Energy Efficiency
Class
Characteristics when operating with the preferred fuel
Useful efficiency at nominal
heat output
Useful efficiency at
minimum heat output
(indicative)
Other control options (multiple selections possible)
room temperature control, with presence detection
room temperature control, with open window
detection
single stage heat output, no room temperature
control
two or more manual stages, no room temperature
control
with mechanic thermostat room temperature
control
with electronic room temperature control
with electronic room temperature control plus day
timer
with electronic room temperature control plus
week timer