![EdilKamin MYRNA Installation, Use And Maintenance Manual Download Page 55](http://html1.mh-extra.com/html/edilkamin/myrna/myrna_installation-use-and-maintenance-manual_2360751055.webp)
55
ENGLISH
USER
MAINTENANCE
Make sure that the ash tray, once re-mounted, is properly positioned in its housing, if not the glass may break by
hitting it.
Ensure that the burning pot is properly positioned in its housing following maintenance, otherwise the stove may
have problems igniting.
Using the stove without cleaning the burning pot can cause the gas in the combustion
chamber to ignite….leading to burst/glass breakage.
1. Open the combustion chamber door (P) using the removable handle provided.
2. The burning pot (A) slips into position in its housing. Empty the ash tray (B) and burning pot into a non-flammable
container (the ashes may still contain embers and/or hot parts) or vacuum if cold. Vacuum out the interior of the
combustion chamber, the bed, and the compartment around the burning pot into which the ash falls.
3. Scrape the burning pot with the provided scraper and clean out any obstructed holes.
4. If necessary, clean the glass when cold using a dedicated product (e.g. Glasskamin), which your dealer should have.
Do not vacuum up hot ash; this damages the vacuum cleaner and may cause a fire.
DO NOT DUMP THE CLEANING RESIDUE INTO THE PELLET TANK.
(P)
A
B