EdilKamin CELIA Air Tight Installation, Use And Maintenance Manual Download Page 9

9

ENGLISH

INSTALLER

REMARKS ON INSTALLATION

REMARKS ON INSTALLATION

Note that:

Note that:
•  installation must be carried out by authorised

•  installation must be carried out by authorised
technical personnel;

technical personnel;
the appliance must be installed and operated in

the appliance must be installed and operated in
compliance with local and national law and European

compliance with local and national law and European
regulations. The Italian reference standard is UNI

regulations. The Italian reference standard is UNI
10683; in France one must follow the instructions in the

10683; in France one must follow the instructions in the
DTA (Document Technique d’Application Référence

DTA (Document Technique d’Application Référence
Avis Technique), www.cstb.fr

Avis Technique), www.cstb.fr
•  if installed in a condominium, the appliance must

•  if installed in a condominium, the appliance must
be approved by the administrator;

be approved by the administrator;
•  if installed in public premises, check and follow

•  if installed in public premises, check and follow
local regulations for this type of installation.

local regulations for this type of installation.
Here are a few general instructions, although these do

Here are a few general instructions, although these do
not obviate the need to comply with local regulations

not obviate the need to comply with local regulations
and do not affect the installer’s liability for the

and do not affect the installer’s liability for the
installation.

installation.
Remember that Rada Air Tight C is sealed, in other

Remember that Rada Air Tight C is sealed, in other
words, if it is installed correctly with the air inlet pipe

words, if it is installed correctly with the air inlet pipe
connected to the outside, it takes the majority of the

connected to the outside, it takes the majority of the
air from the outside. For different countries, check if

air from the outside. For different countries, check if
there are particular installation conditions allowed for

there are particular installation conditions allowed for
sealed stoves.

sealed stoves.

Checking the suitability of the installation
space

•  The room must have a volume of at least 30 m

3

•  The floor must be able to bear the weight of the 

product and its accessories* (see the note in the 
paragraph on the heat protection)

•  Level the appliance
•  Pursuant to Standard 10683 rev. 2012 point 6.3, in 

Italy you can also install the appliance in bedrooms 
or in rooms which already include a product that 
takes air from it for combustion, provided that the 
air inlet is connected to the outside

•  Do not install the product in spaces where there is 

a risk of fire or explosion

•  In Italy, check the compatibility pursuant to UNI 

10683 and UNI 7129 in the presence of gas fired 
products.

INSTALLATION

Protection from heat and safety clearances

The surfaces of the building adjacent to the product
must be protected against overheating.
The insulation to be used will depend on the type of
surface in question.

The appliance must be installed in accordance with
the following safety instructions:
- minimum clearance at the sides 10 cm and back of
5 cm from flammable materials
- no flammable materials may be kept closer to the
front of the appliance than 80 cm.
If connected to a wooden or otherwise flammable wall,
the flue must be appropriately insulated.

If installed on a flammable or combustible floor, or
which is not capable of bearing its load*, use steel or
glass plates under the stove to distribute the load.
Contact the retailer for this type of optional.

Positioning the product

The product is designed to operate in all climate
conditions. In special circumstances, such as strong
wind, the safety devices may intervene to switch the
appliance off.
Contact the authorised Edilkamin Technical Assistance
Centre.

Summary of Contents for CELIA Air Tight

Page 1: ...EN Installation use and maintenance page 2 CELIA Air Tight CELIA Air Tight C PELLET STOVE...

Page 2: ...LIA AIR TIGHT Performance declaration DoP EK n 191 Moreover the company hereby declares that the CELIA AIR TIGHT C CELIA AIR TIGHT wood pellet stoves satisfy the requirements of the following European...

Page 3: ...nd for anything not specifically indicated in the manual observe local regulations The diagrams provided in this manual are for illustration purposes only they do not always strictly refer to your spe...

Page 4: ...y become soiled the flue may catch fire and environmental damage may ensue Cleaning the combustion chamber when hot DO NOT CLEAN WITH A VACUUM CLEANER WHEN HOT You could damage the vacuum cleaner and...

Page 5: ...ENGLISH USER INSTALLER DIMENSIONS DIMENSIONS cm Celia Air Tight Celia Air Tight C 54 27 27 57 5 111 33 30 24 2 27 27 58 5 5 54 111 33 24 8 cm smoke outlet 8 cm smoke outlet 13 cm coaxial 6 cm air inta...

Page 6: ...kW Efficiency 92 8 89 9 CO emissions at 13 O2 0 005 0 017 Fumes temperature 137 119 C Fuel consumption 1 6 0 6 kg h Tank capacity 16 kg Draw 11 10 Pa Autonomy 10 27 ore Heatable volume 190 m3 Fume du...

Page 7: ...Storage disposal or possible recycling must be provided by the user in compliance with relative provided by the user in compliance with relative applicable laws applicable laws Each handling operation...

Page 8: ...CKING INSTALLER DO NOT REMOVE THE PRODUCT FROM THE PALLET BEFORE OPENING THE DOOR AND LOOSENING THE SCREWS THE DRAWINGS ARE FOR GUIDANCE ONLY USEFUL FOR THE INSTALLATION BUT THEY MAY NOT REFER TO THE...

Page 9: ...utside it takes the majority of the air from the outside For different countries check if air from the outside For different countries check if there are particular installation conditions allowed for...

Page 10: ...th THE FUMES DUCT THE FUMES DUCT Further to the general prescriptions for the fumes duct and flue the fumes duct may not be made of flexible metal material must be insulated if routed through unheated...

Page 11: ...er conditions must be anti downdraught must have an internal cross section equivalent to that of the flue and a fumes outlet at least double that of the interior of the flue for dual flues which shoul...

Page 12: ...ct or behind a radiator Installing it in front of the appliance will create unpleasant draughts The air may be drawn from an adjacent room only if the flow is taken from permanent unobstructed opening...

Page 13: ...tion of the stove The electrical system must be compliant check the operation of the earth in particular Edilkamin is not responsible for malfunctions resulting from an improperly earthed system The p...

Page 14: ...e not to touch the smoke discharge pipe if hot FUEL Use UNI EN ISO 17225 2 category A1 wood pellets Use UNI EN ISO 17225 2 category A1 wood pellets or similar regulatory products with the following or...

Page 15: ...thus reducing the power EASY TIMER manual automatic is used to pro gramme the switch ing off on after a set number of hours maximum 12 hours OPTIONAL CONNECTIONS The technician can supply on request...

Page 16: ...igures user of the product operations not protected by password installer operations with dedicated password because any errors can jeopardise the product s operations and SECURITY Edilkamin technical...

Page 17: ...ion the language is not set the adjacent language selection screen will ap pear Choose the language with the buttons and confirm with OK REMOTE CONTROL POWER SAVING After 20 of non use the backlightin...

Page 18: ...ing the remote control Maintenance necessary symbol Appears after a certain number of hours of operation The relative function is active Relax airKare EasyTimer Crono EasyTimer and Crono cannot be act...

Page 19: ...e the product s air power depends on the room temperature or is set by the user Setting Indicates that the remote control is in the setting mode The settable value will appear in the bottom bar Digits...

Page 20: ...utton on the remote control or due to an external contact timer telephone dialler From the OFF page press the ON OFF button for 3 seconds to access the ON page ON STATUS The product is active and can...

Page 21: ...Simply wait without taking any action During the switch off the display will show the word OFF If time scheduling is active the status bar will alternately show 3 seconds the status and the programmin...

Page 22: ...ing the and buttons For example press any button and the display will activate then press the button For example press any button and the display will activate then press the button flame symbol The s...

Page 23: ...ducted fans 2 and 3 FAN ADJUSTMENT The setting can be made with the stove turned OFF or ON If the backlight is switched off it can be activated by pressing any button Pressing the or button will make...

Page 24: ...ilable in all modes automatic manual and timer based Press and hold the button to activate the Relax function Its activation on the display will be signalled by the arrow relative to the Relax button...

Page 25: ...tional feature on other models check which model you have The function if available can be activated with the stove either on or off in any mode except in alarm mode The airKare can be activated by pr...

Page 26: ...our intervals By activating the Easy Timer function with the product off the user sets the switch on time Pressing the OK button or after 5 without pressing any button the countdown will start with 5...

Page 27: ...wise it works with the power Pressing the button allows for switching from Temperature Timer to Power Timer and vice versa Pressing the button activates or deactivates the timer pre programmed from th...

Page 28: ...items appear in the following order 01 STAND BY 02 PELLET LOAD 03 CHRONO PROG TIMER 04 T1 T2 05 DATE HOUR TIME 06 C F 07 LANGUAGE 08 DISPLAY 09 INFO 10 SOFTWARE 11 DATA 12 ALARMS 13 AUGER MOT ON OFF...

Page 29: ...ature set point is reached To access the function from the main menu as indicated in the Menu section above press the MENU button The menu items can be scrolled with the and buttons and the item can b...

Page 30: ...es the function and the display will propose to choose how many minutes must pass before the devices switches off in stand by mode es 5 minutes The and buttons can be used to modify the time and the b...

Page 31: ...SER INSTRUCTIONS USER To access the function from the main menu as indicated in the Menu paragraph above press the MENU button The menu items can be scrolled with the and buttons and the item can be e...

Page 32: ...ONS USER CHRONO PROG TIMER To access the function from the main menu as indicated in the Menu section above press the MENU button The menu items can be scrolled with the and buttons and the item can b...

Page 33: ...y and confirm with the button The cursor rectangular and 2 pixels wide positions itself on 00 00 The time at the top RH shows the start of the time slot The word SET appears with the pre set level for...

Page 34: ...P5 After reaching 23 30 you must go backwards If you shift by pressing and holding the and buttons for more than 2 you copy the previous level onto the next level with a 1 2 h frequency per second The...

Page 35: ...Only if stand by is on the product switch on at the reached temperature Pressing the button briefly allows you to exit the programming but the programme will not activate To activate it you must brief...

Page 36: ...line T1 is the lowest temperature T2 the highest Use the and buttons to move to set point T2 setting Modify the values with the and buttons and confirm with the button Pressing the button automaticall...

Page 37: ...UCTIONS To access the function from the main menu as indicated in the Menu section above press the MENU button The menu items can be scrolled with the and buttons and the item can be entered with the...

Page 38: ...on the second line You can switch from C to F using the and buttons and then confirm with the button and exit Pressing the OK button automatically takes you back to the first level USER USER INSTRUCT...

Page 39: ...back to the first level To access the function from the main menu as indicated in the Menu section above press the MENU button You can scroll the menu items with the and buttons and enter the item wit...

Page 40: ...40 ENGLISH USER USER INSTRUCTIONS DISPLAY It allows you to choose the background of the display...

Page 41: ...tic meaning of the messages and values and may ask you to read them to him her if you experience problems Exit with the following button USER To access the function from the main menu as indicated in...

Page 42: ...e following button USER USER INSTRUCTIONS To access the function from the main menu as indicated in the Menu paragraph above press the MENU button The menu items can be scrolled with the and buttons a...

Page 43: ...ons The alarms are arranged from the most recent to the oldest SCREW FEEDER ON OFF FOR THE TECHNICIAN ONLY ON INDICATION OF THE AFTER SALES DEPARTMENT PELLET LEVEL SENSOR FOR THE TECHNICIAN ENABLING E...

Page 44: ...the Type of Flame setting with the button and then modify the correction value with the and buttons Use the button to exit and return to the Technical Menu You must enter with the installer password...

Page 45: ...n scroll the Technical Menu items with the and buttons until you reach PELLET TYPE You can enter the Pellet Type setting with the following button and modify the value with the and buttons Use the but...

Page 46: ...used to conduct the requested checks agreed upon with the technician Scroll between the Nominal Max or Minimum Min function using the and buttons and modify the value from OFF to ON with the and butt...

Page 47: ...uttons and modify the value with the and buttons If you entered the Technical Menu with the installer password only the installer parameters will appear otherwise all the other parameters will be show...

Page 48: ...uct is controlled via the SAVE PANEL FUNCTIONS To switch on the product press the On Off button for a few seconds To set the power level with the product on press the power button once Pressing it rep...

Page 49: ...eaning mode in work mode Stove cooling Stove in alarm mode Stove cooling Stove off due to blackout Stove in warning mode Digits ON active LED1 LED2 LED3 and LED4 Digits OFF active LED1 and LED2 Digits...

Page 50: ...E Before doing any maintenance disconnect the appliance from the mains Regular maintenance is essential to keep the appliance in good working order Failure to service the product properly will prevent...

Page 51: ...tment around the burning pot into which the ash falls 3 Scrape the burning pot with the provided scraper and clean out any obstructed holes 4 If necessary clean the glass when cold using a dedicated p...

Page 52: ...basis by an authorized technician according to local and national regulations SEASONAL MAINTENANCE to be carried out by the technical assistance centre This consists of cleaning the stove inside and o...

Page 53: ...w the reason see below Do not disconnect from the power supply To restart the product wait for the switch off sequence to terminate and then press the ON OFF button of the remote control or the simpli...

Page 54: ...ing pot Try switching it on with a solid ecological igniter contact the technician beforehand and follow the instructions of the igniter supplier very carefully The operation must be regarded purely a...

Page 55: ...Contact the technician A13 Ducting room temperature probe if present fault The product is operating in manual mode Contact the technician A14 Ducting room temperature probe if present fault The produc...

Page 56: ...ct is working but it must be serviced by an authorised Edilkamin technician LACK OF COMMUNICATION In case of a prolonged lack of communication between the stove and the remote control the Bluetooth tr...

Page 57: ...nsor is installed and has been activated When the level sensor intervenes the circuit board emits a single beep in any switch on or work status and the moving reserve symbol will appear on the display...

Page 58: ...reloading the pellets the stove must be restarted manually If the pellets are reloaded and there is an ignition request coming from the timer the stove will restart If the sensor intervenes with the s...

Page 59: ...59 ENGLISH...

Page 60: ...cod 942162 GB 09 20 A w w w e d i l k a m i n c o m 942162 GB...

Reviews: