ENGLISH

INSTALLER

DATA

Information of the product’s operation log can be scrolled with the 

 and 

 buttons 

USER INSTRUCTIONS

To access the function from the main menu (as indicated 
in the Menu section above), press the MENU button. 

You can scroll the menu items with the 

 and 

 

buttons, and enter the item with the 

 button 

Pressing the  

  button automatically takes you to the first level.

DATA

N° ACC. = 236

DATA

WORKING HOURS = 236

Summary of Contents for Celia Air Tight Plus

Page 1: ...EN Installation use and maintenance page 2 Celia Air Tight Plus Celia Air Tight Plus C PELLET STOVE For all updates visit www edilkamin com...

Page 2: ...S SERIAL NO Rating plate CELIA AIR TIGHT PLUS C CELIA AIR TIGHT PLUS Performance declaration DoP EK n 192 Moreover the company hereby declares that the CELIA AIR TIGHT PLUS C CELIA AIR TIGHT PLUS wood...

Page 3: ...nd for anything not specifically indicated in the manual observe local regulations The diagrams provided in this manual are for illustration purposes only they do not always strictly refer to your spe...

Page 4: ...ome soiled the flue may catch fire and environmental damage may ensue Cleaning the combustion chamber when hot DO NOT CLEAN WITH A VACUUM CLEANER WHEN HOT You could damage the vacuum cleaner and risk...

Page 5: ...ENSIONS 12 18 5 6 cm ducting 6 cm ducting 6 cm air intake 54 27 27 8 cm smoke outlet 57 5 111 33 30 2 24 27 27 58 5 5 12 18 5 8 cm smoke outlet 13 cm coaxial 54 111 33 24 DIMENSIONS cm Celia Air Tight...

Page 6: ...6 2 7 kW Efficiency 90 7 89 9 CO emissions at 13 O2 0 001 0 017 Fumes temperature 182 119 C Fuel consumption 2 2 0 6 kg h Tank capacity 16 kg Draw 11 10 Pa Autonomy 7 27 ore Heatable volume 250 m3 Fu...

Page 7: ...n compliance with relative applicable laws applicable laws Each handling operation must be performed in vertical position by appropriate means and in accordance with current safety regulations Do not...

Page 8: ...ORE OPENING THE DOOR AND LOOSENING THE SCREWS THE DRAWINGS ARE FOR GUIDANCE ONLY USEFUL FOR THE INSTALLATION BUT THEY MAY NOT REFER TO THE SPECIFIC MODEL Stoves are delivered with the coatings fitted...

Page 9: ...utside it takes the majority of the air from the outside For different countries check if air from the outside For different countries check if there are particular installation conditions allowed for...

Page 10: ...th THE FUMES DUCT THE FUMES DUCT Further to the general prescriptions for the fumes duct and flue the fumes duct may not be made of flexible metal material must be insulated if routed through unheated...

Page 11: ...er conditions must be anti downdraught must have an internal cross section equivalent to that of the flue and a fumes outlet at least double that of the interior of the flue for dual flues which shoul...

Page 12: ...ct or behind a radiator Installing it in front of the appliance will create unpleasant draughts The air may be drawn from an adjacent room only if the flow is taken from permanent unobstructed opening...

Page 13: ...tion of the stove The electrical system must be compliant check the operation of the earth in particular Edilkamin is not responsible for malfunctions resulting from an improperly earthed system The p...

Page 14: ...by a grille you will find several optional extras at your reseller air duct pipe 3 metres 6 cm diameter Y deviation for duct pipe 6 cm diameter various models of ducting vents Bent Split Origami Shar...

Page 15: ...to touch the smoke discharge pipe if hot FUEL Use UNI EN ISO 17225 2 category A1 wood pellets Use UNI EN ISO 17225 2 category A1 wood pellets or similar regulatory products with the following or simi...

Page 16: ...vided if for reasons of use or installation the set ventilation does not allow the necessary heat dissipation the maximum ventilation is automatically started The product also has the following supple...

Page 17: ...roduct The Mind APP T M useful for all functions at home with direct connection or outside the home with internet connection and registration If necessary a few functions can also be managed from a SA...

Page 18: ...ler or remote On Off or Thermostat Thermostat on home automa tion contact Thermostat in place of the ambient probe on the elec tronic board ACTION The product turns on off without any modulation the p...

Page 19: ...nd after a further 10 the display switches off If any button is pressed with the display on the counter resets If any button is pressed while the display is off the display and the backlighting will s...

Page 20: ...oblem on the board In any case contact the TAC The relative function is active Relax airKare EasyTimer Crono EasyTimer and Crono cannot be activated simultaneously Reserve indicator It switches on if...

Page 21: ...T POINTS Setting of the various SET POINTS temperature power fan speed Automatic or Manual mode the product s air power depends on the room temperature or is set by the user Indicates that the product...

Page 22: ...wait without taking any action During switch off the display shows the message SHUTDOWN If time programming is active the status and programming are displayed alternately 3 seconds on the status bar...

Page 23: ...ple press any button and the display will activate then press the button flame symbol The setting can be confirmed with the button or by waiting 5 without pressing any button After confirming SET will...

Page 24: ...of the fan being edited appears F1 The fan speed can be increased or decreased with or in the following sequence 1 2 3 4 5 AUTO for the front fan 1 OFF 1 2 3 4 5 AUTO for ducted fans 2 and 3 with but...

Page 25: ...reduces its power output and after a few minutes switches the fan off too NOTE While the Relax function is active it is not possible to increase the power to level P5 USER AIRKARE FUNCTION This funct...

Page 26: ...time can be set with hour intervals By activating the Easy Timer function with the product off the user sets the switch on time Pressing the OK button or after 5 without pressing any button the countd...

Page 27: ...oom temperature otherwise at the power setting Pressing the button allows for switching from Crono in Temperature and Crono to Power and vice versa Briefly pressing the button activates or deactivates...

Page 28: ...ons from the techni cian Therefore we do not report the complete explana tion in this document DISPLAY INFO SOFTWARE DATA ALARMS PELLET FALL PELLET SENSOR TECHNICAL MENU SET TEMPERATURE The set point...

Page 29: ...with the and buttons and enter the item with the button After entering the Stand by function the display will show the name of the function on the first line of the status bar and the current value o...

Page 30: ...PELLET LOADING Allows you to load pellets after the pellet tank has been completely emptied Useful for the technician during the initial start up Available only in the OFF status Any attempt to activ...

Page 31: ...RH shows the start of the time slot Use the and buttons to scroll the time with 1 2 hour steps by moving the cursor and displaying the pre set level Choose the day of the week by scrolling the and but...

Page 32: ...an be used to modify the temperature levels OFF T1 and T2 or the power levels OFF P1 and P5 After reaching 23 30 you must go backwards If you shift by pressing and holding the or buttons for more than...

Page 33: ...e main page USER INSTRUCTIONS The copied day of the week flashes and you can shift to the next day using the and buttons USER NOTES The switching on and off of the product can be forced with the timer...

Page 34: ...is the lowest temperature T2 the highest Use the and buttons to move to set point T2 setting To access the function from the main menu as indicated in the Menu section above press the MENU button You...

Page 35: ...MENU button You can scroll the menu items with the and buttons and enter the item with the button After entering the Date Time function the display will show the name of the function on the first lin...

Page 36: ...nu as indicated in the Menu section above press the MENU button You can scroll the menu items with the and buttons and enter the item with the button Modify the language using the and buttons then exi...

Page 37: ...tons and and confirm with OK button STBY BRIGHTNESS Indicates the backlight percentage of the display be fore entering energy saving mode TIME ON Indicates the time the display remains illuminated STA...

Page 38: ...gnostic meaning of the messages and values and may ask you to read them to him her if you experience problems INSTALLER Pressing the button automatically takes you to the first level To access the fun...

Page 39: ...nly under the guidance of the Technical Assistance Centre Leonardo indicates the target value set and read To be read only under the guidance of the Technical Assistance Centre Fan1 indicates the outp...

Page 40: ...cates the firmware version of the electronic board basic board the firmware version of the control panel the database associated by the Technical Assistance Centres with the products To be read only u...

Page 41: ...SER INSTRUCTIONS To access the function from the main menu as indicated in the Menu section above press the MENU button You can scroll the menu items with the and buttons and enter the item with the b...

Page 42: ...an The meaning of the abbreviations is in the dedicated paragraph The alarms are arranged from the most recent to the oldest Exit with the button PELLET SENSOR Allows you to set ON or OFF of the pelle...

Page 43: ...t to seize up Information on how to use these functions is only available to technicians in the appropriate web area After entering the Technical Menu the first item FLAME TYPE will appear You can ent...

Page 44: ...Pellet Type setting with button and the value can be modified with button and Use the button to exit and return to the Technical Menu In correct installation conditions with the Service Centre parame...

Page 45: ...p to the item PARAMETERS You enter the Parameters with button the first parameter is displayed Scroll through the parameters with and and the value can be modified with buttons and If you entered the...

Page 46: ...activate the speed of the ducting fan at maximum ON OFF NUMBER OF FANS enables or disables the possibility for the end customer to operate the fan if present ROOM INPUT allows to choose which item th...

Page 47: ...uct is controlled via the SAVE PANEL FUNCTIONS To switch on the product press the On Off button for a few seconds To set the power level with the product on press the power button once Pressing it rep...

Page 48: ...eaning mode in work mode Stove cooling Stove in alarm mode Stove cooling Stove off due to blackout Stove in warning mode Digits ON active LED1 LED2 LED3 and LED4 Digits OFF active LED1 and LED2 Digits...

Page 49: ...E Before doing any maintenance disconnect the appliance from the mains Regular maintenance is essential to keep the appliance in good working order Failure to service the product properly will prevent...

Page 50: ...ompartment around the burning pot into which the ash falls 3 Scrape the burning pot with the scraper and clean out any obstructed holes 4 If necessary clean the glass when cold using a dedicated produ...

Page 51: ...basis by an authorized technician according to local and national regulations SEASONAL MAINTENANCE to be carried out by the technical assistance centre This consists of cleaning the stove inside and o...

Page 52: ...w the reason see below Do not disconnect from the power supply To restart the product wait for the switch off sequence to terminate and then press the ON OFF button of the remote control or the simpli...

Page 53: ...ing pot Try switching it on with a solid ecological igniter contact the technician beforehand and follow the instructions of the igniter supplier very carefully The operation must be regarded purely a...

Page 54: ...Contact the technician A13 Ducting room temperature probe if present fault The product is operating in manual mode Contact the technician A14 Ducting room temperature probe if present fault The produc...

Page 55: ...ct is working but it must be serviced by an authorised Edilkamin technician LACK OF COMMUNICATION In case of a prolonged lack of communication between the stove and the remote control the Bluetooth tr...

Page 56: ...nsor is installed and has been activated When the level sensor intervenes the circuit board emits a single beep in any switch on or work status and the moving reserve symbol will appear on the display...

Page 57: ...reloading the pellets the stove must be restarted manually If the pellets are reloaded and there is an ignition request coming from the timer the stove will restart If the sensor intervenes with the s...

Page 58: ...58 ENGLISH...

Page 59: ...59 ENGLISH...

Page 60: ...cod 942163 GB 07 22 B w w w e d i l k a m i n c o m 942163 GB...