TECHNICAL DATA as per EN 14785
KIRA H 22
VyDA H 22
KIRA H 18
VYDA H 18
KIRA H 22
VyDA H 22
KIRA H 18
VYDA H 18
Nominal power
Reduced power
Available power
22,5
18,7
4,9
kW
Heat output to water
20
16,3
3,8
Efficiency
92,7
93,3
95,1
%
CO emissions at 13% O
2
0,012
0,013
0,007
%
Smoke temperature
114
101
54
°C
Fuel consumption
5,1
4,2
1,1
kg/h
Tank capacity
37
kg
Recommended draught
11
11
11
Pa
Autonomy
7
9
33
hours
Water content
20
l
Maximum operating pressure
2
bar
Maximum operating temperature
90
°C
Heatable volume *
585
485
m
3
Smoke outlet diameter (male)
80
mm
Air intake diameter (male)
50
mm
Weight with packaging (Kira H)
280
kg
Weight with packaging (Vyda H ce-
ramic)
260
kg
Weight with packaging (Vyda H stone)
260
kg
tecHnIcAL DAtA foR sIZInG tHe fLUe
which must in any case satisfy the requirements of this sheet and the installation instructions for the product
Nominal power
KIRA H 22
VyDA H 22
KIRA H 18
VYDA H 18
Smoke temperature at outlet
137
122
°C
Minimum draw
0,01
Pa
Smoke flow rate
15,1
13,4
Rps
* The heatable volume is calculated for a house insulated pursuant to Italian Law 10/91 and subsequent amendments,
and a heating demand of 33 Kcal/m³ hour.
eLectRIcAL sPecIfIcAtIons
Power supply
230 V AC +/- 10% 50 Hz
Mean absorbed power
50 - 80 W
Power absorption during ignition
300 W
Protection rating
Fuse 4 AT 250 V AC 5x20
tecHnIcAL DAtA