42
ENGLISH
INSTALLATION
T
INSTALLER
HEATING WITH PUFFER (inertial storage tank) AND BOILER (domestic hot water storage tank)
IT is configuration “3” in the parameters.
NOTE:
In Italy the systems must be separated if the power exceeds 35 kW.
NOTE:
Given the product’s power, we do not recommend using it to produce instantaneous domestic hot water.
The product adjusts in relation to the water temperature and switches on/off on the basis of
the PUFFER temperature (P).
The room temperature measured by the thermostat (T) adjusts the secondary circuit pump
(P2)
The product has the main aim of heating the domestic hot water storage tank.