2. Preparing SD Card
SD card which is in the delivery set, doesn't require any preliminary preparation. It has a configuration text file
CONFIG.INI containing Recorder's settings.
If a new memory card needs to be used, first make sure that the file system installed on the card is FAT32 or ExFat. Next,
install a new SD into the Recorder. The Recorder will generate a configuration file. With the first use of a new SD card a
long initialization is permissible (up to 1 minute).
3. Recording
To start recording press the REC button once for 1 second. The red LED (VD1) flashes once and recording starts.
During recording, the LED flashes in 2 series, the number of flashes showing:
To stop recording, press the REC button once for 1 second. Red LED will be on to indicate recording has stopped.
DO NOT REMOVE MEMORY CARD DURING OPERATION OR WHILE THE LED IS ON
Failure to do so may damage the recorded file.
Note: Any number of flash series that is different from the above mentioned states for one of the following contingency
situations: 3 flashes - rechargeable battery is discharged, constant flashes of red LED indicate microSD card failure (full,
can not be read or not available).
4. Record Playback
The Recorder switches from standby mode to playback mode after a single short pressing of the PLAY button for 1
second. The Recorder start playing the last file recorded, indicating battery status with periodic green flashes (VD2).
The flashing pattern for assessing battery level is similar to the recording process. Recording can be played back
through the built-in speaker or headphones (during this process the way to playback the file cannot be changed).
When the end of the current recording is reached, or after moving to the end of the recording using navigation functions,
playback stops, which is indicated by a rapid blinking of the green indicator. After that, if neither of the buttons id
pressed for 10 seconds, the Recorder goes to standby mode. To exit playback mode press the PLAY button for long.
5. Configuring the Recorder. Editing configuration file through word processor.
First make sure the Recorder is not in record or playback mode. Then remove the microSD card from the Recorder.
Using microsd-USB or SD-microSD connect the card to the PC, a smartphone, or tablet. Open the Config_Card24.ini
file using word processor, and start editing. To set the recording parameter, as well as to enable / disable settings,
select the corresponding value in the line with the parameter after the “=” symbol
Configurator program for creating a configuration file.
The supplied SD card contains a folder with the corresponding software. There is Confiq_card24 prog program in this
folder. Also, this program is available for download from www.ts-market.com
● Run the Confiq_card24 prog program on your device, select the required settings and click the button 'Download new
settings'
● This program generates a new configuration file for your Recorder.
● Delete the old configuration file from the microSD card replacing it with the newly created one.
This program is designed as a java application, it uses any browser available on the device (your PC, tablet,
smartphone, etc.). The program operates offline (no internet connection needed).
Note: before removing the memory card, the Recorder should not be in one of the operating modes, all its indicators
being off. Failure to comply with this requirement may lead to an incorrect termination of the process operating the
memory card and to the loss of all information on it.
Important! In the mode of simultaneous recording on 2 cards, the recorder writes only in 16/16 mono format, and the
records are not marked with a digital signature.
Detailed information on the operation, functions and programming of the Recorder is available in the full
operating instructions on the company's website www.ts-market.com.
In Box:
1. Recorder;
2. SD card;
3. Headphones with 3.5 mm jack
4. Charging cable;
5. Short operating instructions with a warranty card
6. Package box
Number of flashes
Battery charge level (1st series)
Free memory capacity (2nd
series)
1
80-100%
75-100%
2
20-80%
50-75%
3
2-20%
25-50%
4
1-25%