2010ECL-NYC SERIES SIGNAL MONITOR
OPERATIONS MANUAL
Eberle Design Inc.
Page 15
To enable channel pair for FYA operation, place the
Option DIP Switch labeled “FYA x”
(where “x” is 1, 2, 3, 4) in the On position. When the “FYA x” switch is in the Off position, both
channels 1, 3, 5, 7 and the associated protected Green channel (13, 14, 15, 16) operate in
standard fashion. See Section 4.4.8.1.
2.20.3 FYAC (COMPACT) MODE-H
The Model 2010-NYC does support FYA Mode H operation.
- WARNING -
IF THE PERMISSIVE FLASHING YELLOW ARROW AND PROTECTED GREEN
ARROW CHANNEL ASSIGNMENTS ARE SWAPPED SUCH THAT THE FYA INPUT
IS MONITORED ON CHANNELS 13:16 GREEN:
1) The Flashrate Fault function monitors the enabled flashing Yellow Arrow input of
channels 1, 3, 5, 7. The Flashrate Fault function must be disabled. See Section
4.5.7.
2) Exit Flash into Start-up in all Yellow signals is not permitted.
3) Time of Day flash in all Yellow signals is not permitted.