8-59
CAUTION!
Do not alter the file in any way other than what has been
specified.
This will deactivate COM ports 2 and 3. By deactivating these ports, Sonar will report to Discover
that only one sensor is to be used on COM1 to parse the necessary sensor information. Therefore,
Discover will not display any errors if a sensor is not connected to COM2 or COM3.
If steps 3 through 6 were not carried out, then these errors would be reported in the Diagnostic
window, as shown in
Figure 8-14: Diagnostic Window, Reporting Ports Inactive Error
7.
Close the SonarSerial.ini file and restart the Sonar application by double-clicking on the Sonar
icon in the main Sonar Remote Desktop Screen, as shown in
FIGURE
8-15
Figure 8-15: Sonar.Exe Desktop Location
8.
Plug the device into COM 1.
9.
Click
Misc.
at the top of the Sonar screen, as shown in
, then
Serial Port Information.
10.
Check
COM1
and set the correct baud rate for that device using the dropdown menu, shown with
a blue arrow in
. When the correct baud rate is set, the State should say
OK,
and
Errors
should not be increasing, as shown circled in green in
. In addition, the correct data
string should also be scrolling in the lower part of the window, as shown by the green arrow,
Summary of Contents for 6205S2
Page 32: ...2 32 Figure 2 2 6205s2 Sonar Head with Adaptor Flange ICD...
Page 33: ...2 33 Figure 2 3 6205s2 Side Scan Transducer...
Page 34: ...2 34 Figure 2 4 6205s2 Side Scan Transducer Details...
Page 35: ...2 35 Figure 2 5 6205s2 Deck Cable Wiring Diagram...
Page 36: ...2 36 Figure 2 6 6205s2 GNSS INS Deck Cable Wiring Diagram...
Page 37: ...2 37 2 6 2 6205s2 Topside Figure 2 7 6205s2 Rack Mounted Topside...
Page 38: ...2 38 Figure 2 8 6205s2 Rack Mount in Case...
Page 41: ...3 41 3 1 2 2 Sonar Processor Endcap and Pinout Drawings Figure 3 5 6205S2 Forward End Cap...
Page 42: ...3 42 6205s2 BATHYMETRIC AND SIDE SCAN SONAR 0025262_REV_A Figure 3 6 6205s2 Aft End Cap...
Page 46: ...3 46 Figure 3 11 6205s2 Acoustic Center Location X Y Z and Bolt Pattern...
Page 47: ...3 47 Figure 3 12 6205s2 with Adaptor Flange Acoustic Center Location X Y Z and Bolt Pattern...