4-39
=
Figure 4-8: Discover 2050 Sub-Bottom Display Window
To perform the pre-deployment checks:
1.
Follow the instructions in
A
CTIVATING THE
T
OPSIDE
section of this manual and activate the Sub-
Bottom amplifiers in Web Relay.
2.
Run a Tap Test – Navigate to the Sub-Bottom Control Tab, shown in
Figure 4-9: The Sub-Bottom Control Tab
3.
In the Sub-Bottom Control Tab, select a Transmit Pulse using the “Pulse” dropdown. Set “Transmit
Level (%)” to “100”. Select the “Transmit On” checkbox. Verify that you can hear the system
transmitting. The transducers should begin transmitting (at 100%) and receive data should begin
scrolling on the Waterfall Display in Discover’s Sub-Bottom display, from right to left.